H7CX OMRON [Omron Electronics LLC], H7CX Datasheet - Page 18

no-image

H7CX

Manufacturer Part Number
H7CX
Description
Multifunction Preset Counter
Manufacturer
OMRON [Omron Electronics LLC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H7CX-A-N AC100-240
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Part Number:
H7CX-AD-N DC12-24
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Part Number:
H7CX-AS-N AC100-240
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
I Self-diagnostic Function
The following displays will appear if an error occurs.
Note: 1. The display for 4-digit models is given in parentheses.
I Response Delay Time When
The following table shows the delay from when the reset signal is
input until the output is turned OFF.
I Output Delay Time
The following table shows the delay from when the present value
passes the set value until the output is produced.
Actual measurements in N and K-2 modes.
Note: The above times may vary slightly depending on the mode or
I Maximum Counting Speed for
The maximum counting speed for batch counter operation is 5 kHz.
The batch counter counts the number of times the count reaches the
set value.
C-104
------
(----)
(See notes 1 and
2.)
ffffff
(ffff)
(See notes 1 and
2.)
e1
e2
e2
1 ms
20 ms
Contact output
Transistor output
Control output type Maximum counting
Minimum reset signal width
Main display
Resetting (Transistor Output)
Batch Counter
2. Display flashes (1-second cycles).
3. Occurs when the present value or the total count value goes below −99,999 (−999 with 4-digit models).
4. Occurs when the present value (or measurement value) reaches 999,999 (9,999 with 4-digit models) under the following conditions:
5. Except when the H7CX is set for tachometer operation.
6. Includes the case where the EEPROM has reached its overwrite lifetime.
operating conditions.
• The output mode is K-2, D, L, or H.
• The H7CX is set for dual counter or tachometer operation.
Multifunction Preset Counter
No change
No change
Not lit
Not lit
sum
Sub-display
30 Hz
5 kHz
30 Hz
5 kHz
speed
0.8 to 1.2 ms
15 to 25 ms
Present value underflow
(See note 3.)
Present value overflow
(See note 4.)
CPU
Memory error (RAM)
Memory error (EEP)
(See note 6.)
Output delay time
16.5 to 24.0 ms
3.7 to 5.6 ms
12.0 to 20.0 ms
0.2 to 0.55 ms
Output delay time
Error
(Reference values)
H7CX
(Reference values)
No change
No change
OFF
OFF
OFF
Output status
I Wiring
Wiring input lines in the same conduit as power lines or other high-
voltage lines may result in malfunction due to noise. Wire the input
lines separately, away from lines carrying high-voltages. In addition,
make the input wiring as short as possible and use shield lines or
metal wiring conduits.
Pay attention to terminal polarity to ensure correct wiring.
I Mounting
Tighten the two mounting screws on the Adaptor. Tighten them alter-
nately, a little at a time, so as to keep them at an equal tightness.
The H7CX’s panel surface is water-resistive (conforming to NEMA 4
and IP66). In order to prevent the internal circuit from water penetra-
tion through the space between the timer and operating panel, attach
a waterproof packing between the timer and installation panel and
secure the waterproof packing with the Y92F-30 Flush-mounting
Adapter.
Either press the reset key or turn ON
reset input.
Either press the reset key or turn ON
reset input. (See note 5.)
Either press the reset key or reset the
power supply.
Reset the power supply.
Reset to the factory settings using the
reset key.
0.5 to 1 mm
Correction method
It is recommended that the space between
the screw head and the adapter should be
0.5 to 1 mm.
No change
No change
No change
No change
0
Set value after
reset