Advanced, Compact Digital Controllers
• IP66/NEMA4 (indoor use) front face.
• Modular structure, one-stock type.
• Heating/cooling control.
• Serial communications (RS-232C and RS-485).
• Temperature and analog inputs.
• High-accuracy: 100 ms sampling (for analog input).
• Advanced tuning which includes fuzzy self-tuning.
• Conforms to international EMC and safety standards.
• AC/DC24V types are also available.
Model Number Structure
I Model Number Legend
Refer to the following when ordering set models.
1. Control Output 1/Control Output 2
Note: E5CK-VR1 and E5CK-QQ1 are not available, but with options.
Ordering Information
I List of Models
Note: A single Output Unit and Option Unit can be mounted to each Base Unit.
E5CK-@@@
Base Unit
Output Unit
Digital Controller
E5CK
AA:
RR:
QR:
CR:
VR:
QQ: Pulse (NPN)/Pulse (NPN)
Without Output Unit (field interchangeable)
Relay/Relay
Pulse (NPN)/Relay
Linear (4 to 20 mA)/Relay
Linear (0 to 10 V)/Relay
1 2 3
Description
Description
E5CK-AA1 AC100-240
E5CK-AA1-500 AC100-240
E5CK-AA1 AC/DC24
E5CK-AA1-500 AC/DC24
E53-R4R4
E53-Q4R4
E53-Q4HR4
E53-C4R4
E53-C4DR4
E53-V44R4
E53-Q4Q4
E53-Q4HQ4H
Model
Model
2. Auxiliary Output
3. Option
1:
01:
03:
B:
F:
Auxiliary output (1 point)
RS-232C serial communication
RS-485 serial communication
Event input (1 point)
Transfer output (4 to 20 mA)
Base Unit
Base Unit with terminal cover
Base Unit
Base Unit with terminal cover
Relay/Relay
Pulse (NPN)/Relay
Pulse (PNP)/Relay
Linear (4 to 20 mA)/Relay
Linear (0 to 20 mA)/Relay
Linear (0 to 10 V)/Relay
Pulse (NPN)/Pulse (NPN)
Pulse (PNP)/Pulse (PNP)
Digital Controller
Specification
Specification
E5CK
®
I-63

Related parts for E5CK

E5CK Summary of contents

Page 1

... CR: Linear ( mA)/Relay VR: Linear ( V)/Relay QQ: Pulse (NPN)/Pulse (NPN) Note: E5CK-VR1 and E5CK-QQ1 are not available, but with options. Ordering Information I List of Models Description Base Unit Note: A single Output Unit and Option Unit can be mounted to each Base Unit. ...

Page 2

... Description Option Unit Inspection Report The Digital Controller can be provided together with an inspection report. Refer to the following legend with the suffix “K” when ordering a model provided together with an inspection report. E5CK-AA1-K, E53-CKF-K I Accessories (Order Separately) Name Terminal Cover E53-COV07 Specifications ...

Page 3

... 200 100 1,700 1,700 1,800 2,300 1,300 300 300 3,000 3,000 3,200 4,100 2,300 E5CK Digital Controller PLII 0 to 1,300 0 to 2,300 16 I-65 ...

Page 4

... The indication accuracy of the R and S thermocouples at a temperature of 200 C or less digit maximum. The indication accuracy of the W thermocouple at any temperature is ( 0.3% of the indicated value whichever is greater) 1 digit maximum. The indication accuracy of the PLII thermocouple at any temperature whichever is greater) 1 digit maximum. E5CK I-66 Digital Controller Thermocouple ...

Page 5

... ON: residual voltage 1.5 V max., OFF: leakage current 0.1 mA max. Communications Interface: Transmission method: Synchronization method: Start-stop synchronization (asynchronous method) Baud rate: Transmission code: Transfer output mA: Permissible load impedance: 500 Resolution: approx. 2,600 100,000 operations min. min. max. min. RS-232C or RS-485 Half-duplex 1.2/2.4/4.8/9.6/19.2 kbps ASCII max. Digital Controller E5CK I-67 ...

Page 6

... Lights during remote opera- tion. AT Flashes during auto-tuning. Dimensions Note: All units are in millimeters unless otherwise indicated. E5CK Panel Cutouts +0.6 60 min. 45 E5CK I-68 Digital Controller A/M Key Press to select the auto operation or manual operation min. 0 Note: 1. Recommended panel thickness mm. ...

Page 7

... Place the Controller with its bottom facing up, and fit the board horizontally into the Connector on the power board (right side of controller). 2. With the power board connected, fit the board vertically into the Connector on the control board (left side of controller E5CK Digital Controller I-69 ...

Page 8

... I Mounting 1. Insert the E5CK Controller into the panel’s mounting hole at the position shown in the figure below. 2. Push the adapter along the Controller body from the terminals up to the panel, and fasten temporarily. 3. Tighten the two fixing screws on the adapter. When tightening screws, tighten the two screws alternately keeping the torque to approximately 0.29 to 0.39 N· ...

Page 9

... Take care not to tighten the terminal screws too tightly. Power Blocks The E5CK has independent power supplies for each of the terminal OUT2 blocks shown below. However, note that the power supplies for blocks C (exclude relay output) and D are shared for the following option unit ...

Page 10

... E53-CK01 Use event inputs under the following conditions: Contact input No-contact input The polarity for no-contact input is as follows Transfer output specifications are as follows mA, load: 500 max., resolution approx. 2600 E5CK I-72 Digital Controller + + GND 9 Relay NPN ...

Page 11

... I Parameters and Menus Note: For more details on the functions of each part and display contents, refer to the E5CK User’s Manual (H78). Protect Mode Limits use of the menu and A/M Keys. The protect function prevents unwanted modification of parameters and switching between the auto and manual operation ...

Page 12

... Only the "PV/SP monitor" and "set point" parameter can be used when this parameter is set to "5." Only the "PV/SP monitor" parameter can be used when this parameter is set to "6." A/M Key Protect Invalidate the function of the A/M Key. off MV Manual Process value 16.0 Manipulated variable MANU indicator E5CK I-74 Digital Controller Mode Set value Calibration x ...

Page 13

... Available when the Controller is in ON/OFF control in heating and cooling control. 0.10 Control Period (Heat Available when the Controller has a relay or voltage output advanced PID control. 20 Control Period (Cool Available when the Controller has a relay or voltage output advanced PID control in heating and 20 cooling control. E5CK I-75 Digital Controller ...

Page 14

... Available only when the Controller has an alarm output. 0.02 Input Shift Upper Limit Available if the input type connected to the Controller is a thermocouple or platinum resistance 0.0 thermometer. Input Shift Lower Limit Available if the input type connected to the Controller is a thermocouple or platinum resistance 0.0 thermometer. E5CK I-76 Digital Controller ...

Page 15

... Enables the Controller to have alarm 1, alarm 2, alarm 3, LBA (loop break alarm), error 1, and error 2 al-2 outputs. Alarm 1 Type Alarm 1 Open in Alarm n-o Alarm 2 Type Alarm 2 Open in Alarm n-o Direct/Reverse Operation or-r Available only when the Controller has an alarm output (see the table on the next page). E5CK Digital Controller I-77 ...

Page 16

... Lower-limit alarm with standby sequence (devia- tion) 8 Absolute-value upper-limit alarm 9 Absolute-value lower-limit alarm 10 Absolute-value upper-limit alarm with standby se- quence 11 Absolute-value lower-limit alarm with standby se- quence E5CK I-78 Digital Controller Alarm output When X is positive Always OFF OFF ...

Page 17

... Automatic Return of Display Mode Hysteresis Available if the Controller is in advanced PID control with the ST set to OFF. 0.2 LBA Detection Width Available only when the LBA (loop break alarm) function of the Controller is selected. 0.2 E5CK I-79 Digital Controller ...

Page 18

... Transfer Output Type Set when the transfer output function is being used. sp Transfer Output Upper Limit Set when the transfer output function is being used. 1300 Transfer Output Lower Limit Set when the transfer output function is being used. -200 E5CK I-80 Digital Controller ...

Page 19

... Internal memory operation is in error Action First, turn the power OFF then back ON again. If the display remains the same, the E5CK Controller must be re- paired. If the display is restored to normal, the probable cause may be external noise affecting the control system. Check for external noise. ...

Page 20

... I Fuzzy Self-tuning Fuzzy self-tuning is a function that enables the E5CK to calculate the most suitable PID constants for the controlled object. Features • The E5CK determines by itself when to perform fuzzy self-tuning. Fuzzy Self-tuning Function The fuzzy self-tuning function has three modes. In SRT (step response tuning) mode, the PID constants are tuned using a step response method at the time the set point is changed ...

Page 21

... SRT is not being executed. Extreme value 2 Extreme value 4 Temperature SP Extreme Extreme value 1 value 3 Time Note: In specific applications where temperature varies periodically due to disturbance, internal parameters need to be adjusted. For details, refer to the E5CK User’s Manual. E5CK I-83 Digital Controller ...

Page 22

... Unit. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. H079-E1-05 In the interest of product improvement, specifications are subject to change without notice. E5CK I-84 Digital Controller Three-year Guarantee Period of Guarantee The guarantee period of the Unit is three years starting from the date the Unit is shipped from the factory ...