MPM-9561 BOSER [BOSER Technology Co., Ltd], MPM-9561 Datasheet

no-image

MPM-9561

Manufacturer Part Number
MPM-9561
Description
60W Open Frame Power Supply for Medical Class
Manufacturer
BOSER [BOSER Technology Co., Ltd]
Datasheet
*Input Voltage: 85~264VAC
*Input Frequency: 47~63Hz at AC input
*Input Current: 2A at 115VAC or 1.5A at 230VAC max.
*Inrush Current: The maximum inrush current will not exceed
*Load Range: The adjustable range of +5V output is around
*Ripple And Noise: The peak to peak ripple and noise for +5V
*Line Regulation: The line regulation for each output is less
*Load Regulation: The load regulation for +5V is less than +/-
*Hold Up Time: The hold up time is longer than 16mS at
*Efficiency: The efficiency is higher than 75% typical while
*Protection: For some reasons the power supply fails to
*Dimensions: 7.62 x 12.7 x 3.87 cm
Features
Features
30A at 115VAC or 60A at 230VAC input, cold start, 25
4.5~5.8V. At factory, the +5V output is set to between
4.95~5.05V at 60% rated load, and +/-12V are checked to be
within the specified voltage accuracy range. The peak load
cannot exceed 5 sec.
output is less 50mV for +/-12V output are less than 100 mV.
Measuring is done by 15MHz bandwidth limited oscilloscope
and terminated each output with a 0.47uF capacitor
than +/-1% while measuring at rated load and +/-10% of the
input changing
1%, for +/-12V is less than +/-5%, measured is done by
changing the measured output load +/-40% from 60% rated
load, and keep all other output at 60% rated load
115VAC input and rated load, which is measured from the end
of the last charging pulse to when the main output drops down
to 95%output voltage
measuring at nominal line and rated load
control itself, the build-in over voltage protection circuit will
shut down the outputs to prevent damaging to external
circuits. The trip point of crowbar circuit is around 5.8V to 7V
for output voltage. The power supply will go into latch off mode
against short circuit or over load conditio
www.boser.com.tw
MPM-9561
o
C
60W Open Frame Power Supply for Medical Class
*Safety: UL 544 / UL 2601-1 / CSA 22.2 No. 601-1 / TUV
*GND Leakage Current: It should be less 100uA at 244VAC
*EMI: FCC docket 20780 curve B / EN55011 B / EN61000-3-2
*EMS: IEC-801-2 8KV air discharge criteria B / IEC-801-3
Safety Standards
Safety Standards
(DIN. VDE 0750T. 1/12.91/EN60601-1L 1990)
input
3V/M / IEC-801-4 0.5KV
0.5
Voltage
Output
+12V
-12V
+5V
Load
Min.
0A
0A
0A
Rated
Load
2.3A
0.5A
5A
11.56
12.7
Max.
Load
3.5A
----
8A
-11.4~-12.6V
4.95~5.05V
11.4~12.6V
Accuracy
Voltage