SLIN-20E1A0 BEL [Bel Fuse Inc.], SLIN-20E1A0 Datasheet - Page 20

no-image

SLIN-20E1A0

Manufacturer Part Number
SLIN-20E1A0
Description
NON-ISOLATED DC/DC CONVERTERS 4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /20 A Outputs
Manufacturer
BEL [Bel Fuse Inc.]
Datasheet
Tunable Loop
Table 2 .General recommended values of R
combinations.
Table 3 .Recommended values of R
load with Vin=12V.
Thermal Considerations
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is
shown below.
October 8, 2009
R
C
R
C
Co
Vo
Δ V
TUNE
TUNE
Co
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /20 A Outputs
TUNE
TUNE
6x47μF
5600pF
1x47μF
1500pF
99mV
220
5V
240
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 •
TM
5x47μF + 330μF
(continued)
2700pF
2x47μF
Polymer
7500pF
240
66mV
3.3V
220
Wind Tunnel
4x47μF
5600pF
TUNE
240
PWBs
and C
2x330μF
Polymer
TUNE
50mV
18nF
2.5V
10x47μF 20x47μF
200
TUNE
12nF
Thermal Test Setup
150
and C
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
to obtain transient deviation of ≤2% of Vout for a 10A step
TUNE
flow
Air
(0.50)
x
12.7_
6x47μF + 2x 330μF
15nF
150
for Vin=12V and various external ceramic capacitor
(3.0)
76.2_
25.4_
(1.0)
Polymer
36mV
33nF
1.8V
150
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
6x47μF + 4x330μF
Polymer
120nF
24mV
1.2V
150
www.belfuse.com
12x330μF
Polymer
120nF
0.69V
12mV
150
20

Related parts for SLIN-20E1A0