HFCT-5103D HP [Agilent(Hewlett-Packard)], HFCT-5103D Datasheet - Page 6

no-image

HFCT-5103D

Manufacturer Part Number
HFCT-5103D
Description
SC Duplex Single Mode Transceiver
Manufacturer
HP [Agilent(Hewlett-Packard)]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HFCT-5103D
Manufacturer:
BROADCOM
Quantity:
6 500
Part Number:
HFCT-5103D
Manufacturer:
AGILENT
Quantity:
20 000
Performance Specifications
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause catastrophic damage to the device. Limits apply to each
parameter in isolation, all other parameters having values within the recommended operating conditions. It should not be
assumed that limiting values of more than one parameter can be applied to the product at the same time. Exposure to the absolute
maximum ratings for extended periods can adversely affect device reliability.
Operating Environment
Transmitter Section
(Ambient Operating Temperature Ta = 0°C to +70°C, V
Receiver Section
(Ambient Operating Temperature Ta = 0°C to +70°C, V
Notes:
1. 2 m/s air flow required.
2. Output power is power coupled into a single mode fiber.
3. The power supply current varies with temperature. Maximum current is specified at V
4. Minimum sensitivity and saturation levels for a FDDI test pattern as defined in FDDI SMF-PMDl with 4B/5B NRZI encoded data that contains a
5. The current excludes the output load current.
Output Center Wavelength
Output Spectral Width (RMS)
Extinction Ratio
Power Supply Current
Output Eye
6
Parameter
Storage Temperature
Operating Temperature
Lead Soldering Temperature/Time
Output Current (other outputs)
Input Voltage
Power Supply Voltage
Parameter
Power Supply Voltage
Parameter
Average Optical Output Power
Parameter
Receiver Sensitivity
Maximum Input Power
Signal Detect - Asserted
Signal Detect - Deasserted
Signal Detect - Hysteresis
Power Supply Current
Data Outputs and Alarm Output
Ambient Operating Temperature
terminations) and end of life.
duty cycle baseline wander effect of 50 kHz and a 2
P
Er
I
Compliant with Bellcore TR-NWT-000253 and ITU recommendation G.957
I
Symbol
l
-
-
P
P
P
I
Symbol
T
-
-
-
-
Symbol
V
T
Dl
Symbol
CC
CC
OUT
O
A
D
A
S
OP
C
CC
- P
D
23-
1 PRBS with 72 ones and 72 zeros inserted (ITU-T recommendation G.958).
Minimum
1261
-
-20
8.2
-
Minimum
-
-8.0
P
-45
-
Minimum
-40
0
-
0
GND
0
Minimum
+4.75
0
0.5
D
CC
CC
+0.5
= 4.75 V to 5.25 V)
= 4.75 V to 5.25 V)
-
-
-
-
-
Typical
80
1360
140
Maximum
7.7
-14
-
Maximum
+85
+70
+260/10
30
+6
Maximum
+5.25
+70
V
CC
CC
= Maximum @ maximum temperature (not including
PECL
100
Maximum
-31
-
-31
-
4.0
nm
nm
mA
mA
Units
dBm
dB
Units
°C
°C
°C/s
V
V
Units
V
°C
Units
dBm
dBm
dBm avg.
dBm.avg
dB
mA
1
1
Notes
-
-
2
-
Notes
-
-
-
-
-
Notes
-
3
Notes
-
-
-
-
5
4

Related parts for HFCT-5103D