MPE-40S-05 MPD [MicroPower Direct, LLC], MPE-40S-05 Datasheet

no-image

MPE-40S-05

Manufacturer Part Number
MPE-40S-05
Description
Single Output, 40W Compact, Enclosed AC/DC Power Supplies
Manufacturer
MPD [MicroPower Direct, LLC]
Datasheet
MPE-40S
Key Features:
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Single Output, 40W
Si
Compact, Enclosed
AC/DC Power Supplies
40W Output Power
Universal 85-264 AC Input
EN 60950 Compliant
Four Single Output Models
Meets EN55022
>300 kHour MTBF
Compact Metal Enclosure
RoHS Compliant
l O
Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz) , See Note 2
Hold-Up Time
Set-Up Time
Rise Time
Temperature Coeffi cient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Safety Ground Leakage Current
Output
General
Parameter
Isolation Voltage
Isolation resistance
EMI/RFI
EMC Compliance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifi cations
Parameter
MTBF
Safety Standards
Vibration
0
Electrical Fast Transients/Bursts On Mains
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
MIL HDBK 217F, 25°C, Gnd Benign
Series
Electrostatic Discharge (ESD)
Conditions
Conditions
Conditions
Conditions
Conditions
RF Field Susceptibility
RH, Non-condensing
Free Air Convection (See Derating Curve)
Cold Start, 115 VAC
Cold Start, 230 VAC
Output to Ground
Input to Ground
Input to Output
5.18 x 3.93 x 1.53 Inches (131.6 x 100.0 x 38.0 mm)
Continuous (Autorecovery)
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
Conducted
IEN 60950, IEC 60950
See Note 3
See Note 4
Universal
Ambient
500 VDC
115 VAC
230 VAC
115 VAC
230 VAC
115 VAC
230 VAC
115 VAC
230 VAC
Surge
3,000
1,500
Min.
Min.
Min.
Min.
Min.
120
115
110
500
300
-10
-20
85
47
20
IEC/EN 61000-4-2, -6, -8, -11
EN 55022; EN 61000-3-2, -3
±0.02
30.0
60.0
Typ.
Typ.
Typ.
Typ.
Typ.
800
300
100
+25
15
60
50
50
36
Vented Metal Enclosure
Max.
Max.
Max.
Max.
Max.
264
370
135
160
+60
+85
0.6
1.0
63
IEC/EN 61000-4-4
IEC/EN 61000-4-5
90
15.4 Oz (0.44 kg)
IEC/EN61000-4-3
% Vout
% Iout
kHours
Units
Units
Units
Units
Units
mSec
mSec
mSec
%/°C
VDC
A Pk
VAC
VAC
kHz
mA
Hz
°C
°C
%

Related parts for MPE-40S-05

MPE-40S-05 Summary of contents

Page 1

... MicroPower Direct EMC Compliance 292 Page Street Suite D Switching Frequency Stoughton, MA 02072 Environmental USA Parameter T: (781) 344-8226 Operating Temperature Range F: (781) 344-8481 Storage Temperature Range E: sales@micropowerdirect.com Cooling W: www.micropowerdirect.com Humidity Physical Case Size Case Material Weight Reliability Specifi cations Parameter MTBF ...

Page 2

... Model Selection Guide Input Model Current (A) Number 115 230 VAC VAC MPE-40S-05 1.2 0.6 MPE-40S-12 1.2 0.6 MPE-40S-15 1.2 0.6 MPE-40S-24 1.2 0.6 Notes: 1. Output voltage tolerance includes the the effects of set point accuracy, line regulation and load regulation. 2. Ripple and noise is measured at 20 MHz bandwidth using a 12 inch twisted pair wire to connect to the power supply ter- minals. A 0.1 µ ...

Related keywords