mpe-100fs MicroPower Direct, LLC, mpe-100fs Datasheet

no-image

mpe-100fs

Manufacturer Part Number
mpe-100fs
Description
Single Output, 100w Compact, Enclosed Ac/dc Power Supplies
Manufacturer
MicroPower Direct, LLC
Datasheet
MPE-100FS
Key Features:
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Single Output, 100W
Compact, Enclosed
AC/DC Power Supplies
100W Output Power
Selectable 88-264 AC Input
EN60950 Approved
Wide Temp Operation
Seven Single Output Models
Meets EN55022
>300 kHour MTBF
Compact Metal Enclosure
Electrical Specifi cations
Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Parameter
Output Voltage
Output Current
Output Voltage Adjustment
Output Voltage Tolerance, See Note 1
Ripple & Noise (20 MHz), See Note 2
Hold-Up Time
Set-Up Time
Rise Time
Temperature Coeffi cient
Short Circuit Protection
Over Voltage Protection
Overload Protection
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Safety Ground Leakage Current
Output
General
Parameter
Isolation Voltage
Isolation resistance
EMI/RFI
EMC Compliance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Reliability Specifi cations
Parameter
MTBF
Safety Standards
Vibration
www.micropowerdirect.com
Electrical Fast Transients/Bursts On Mains
10~500 Hz, 2G 10 min/1 Cycle. Period of 60 min each along X, Y &Z Axis
MIL HDBK 217F, 25°C, Gnd Benign
CAN/CSA-C22.2 No 60950-1-03, ANSI/UL Std No 60950-1, IEC 60950
Electrostatic Discharge (ESD)
Series
Conditions
Conditions
Conditions
Conditions
Conditions
RF Field Susceptibility
RH, Non-condensing
Cold Start, 115 VAC
Cold Start, 230 VAC
Switch Selectable
Output to Ground
Input to Ground
Input to Output
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
See Model Selection Guide
Continuous (Autorecovery)
7.83 x 3.86 x 1.50 Inches (199.0 x 98.0 x 38.0 mm)
Conducted
See Note 3
See Note 4
Free Air Convection
500 VDC
115 VAC
240 VAC
115 VAC
230 VAC
230 VAC
230 VAC
Ambient
Surge
3,000
1,500
Min.
Min.
Min.
Min.
Min.
176
248
115
135
500
300
-10
-20
88
47
IEC/EN 61000-4-2, -6, -8, -11
EN 55022; EN 61000-3-2, -3
1,000
±0.02
IEC/EN 61000-4-4
IEC/EN 61000-4-5
Typ.
30.0
60.0
Typ.
Typ.
IEC/EN61000-4-3
Typ.
Typ.
115
220
100
+25
15
20
30
75
Vented Metal Enclosure
Max.
Max.
Max.
Max.
Max.
132
264
370
135
165
+60
+85
0.7
1.0
63
95
22.9 Oz (0.65 kg)
kHours
mSec
mSec
mSec
Units
Units
%/°C
Units
Units
Units
VDC
A Pk
VAC
VAC
kHz
M
mA
Hz
°C
°C
%
%
%

Related parts for mpe-100fs

mpe-100fs Summary of contents

Page 1

... MPE-100FS Single Output, 100W Compact, Enclosed AC/DC Power Supplies Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Key Features: Input • 100W Output Power Parameter • ...

Page 2

... The overload protection circuit shuts down the output. The unit recovers automatically when the fault condition is removed recommended that a fuse be used on the input of a power supply for protection. For the MPE-100FS series, a 7.5A/250 VAC slow blow should be used. Pin Connections Pin Function ...

Related keywords