Monitor Data Table 4
OCTOBER 2008
Address
100-101
102-103
104-105
106-109
1. The Digital Diagnostic Monitoring values and Alarm/Warning indicators will be set to zero, and Data Ready Bar will be set high, for
2. The data ready bar bit is held high during module power up and prior to the first transceiver sampling of the monitored values. The
3. Bytes 112-119 contain a set of non-latched alarm and warning flags. Users can choose to read these values and use them to ana-
4. The Vendor Specific area is further defined below in Vendor Specific Digital Diagnostic Monitor TX_FAULT Alarm/Warning Interrupt
96-97
98-99
Byte
110
110
110
110
110
110
110
110
111
111
112
112
112
112
112
certain failure mechanisms within the transceiver that do not affect the link capability of the transceiver. Refer to Vendor Specific
Digital Diagnostic Monitor TX_FAULT Alarm/Warning Interrupt on page 37 for additional information on transceiver Digital Diag-
nostic Monitoring status.
bit will be set low after each first successful sampling occurs and remain low until the transceiver looses power or a failure occurs.
The bit must be set low within 1 second of reaching a valid stable power supply level.
lyze the status of the transceiver as an alternative to decoding the real-time values in bytes 96-105. Alarm flags indicate levels that
are likely to be associated with link failures. Warning flags indicate levels that are outside of normal levels, but not necessarily
cause for immediate concern (could be used for end-of-life indicators).
on page 37.
7:6
5:0
Bit
All
All
All
All
All
All
7
6
5
4
3
2
1
0
7
6
5
4
3
Temperature Value
Voltage Value
TX Bias Value
TX Power Value
RX Power Value
Reserved
TX Disable State
Soft TX Disable
AS1 State
RX Rate Select AS0 State
Soft Rate Select
TX Fault
LOS
Data Ready Bar
Control Mode
Table Select (TS)
Temp High Alarm
Temp Low Alarm
Voltage High Alarm
Voltage Low Alarm
TX Bias High Alarm
Diagnostic Data Values, Alarms, Warnings and Status Bits
Name
1
1
1,2
1
1
1,3
1,3
1
1,3
1,3
1,3
Internal Transceiver Temperature (MSB at low address)
TX VDD Voltage (MSB at low address)
Laser Diode Average Current (MSB at low address)
Average Fiber Coupled Power (MSB at low address)
Average Received Power (MSB at low address)
Reserved for future MSA monitored parameters.
State of TX Disable input pin
Read/Write bit that allows software disable of laser. Writing a ‘1’ disables
the laser. Default power value is ‘0’. This bit is internally OR’ed with the
hard TX_DISABLE pin value.
Digital state of AS1 input pin.
Digital state of rate_select input pin.
Not Applicable
State of TX Fault output pin.
Sate of LOS output pin.
Indicates transceiver has achieved power and Digital Diagnostic data is
ready to be read.
Not Applicable
For soft application_select, a 6-bit binary number (TS) that represents the
sequence of the Application code in the AST. It is written by the host for
select module behavior.
Set when internal temperature exceeds the bytes 0-1 level.
Set when internal temperature is below the bytes 2-3 level.
Set when TX VDD exceeds the bytes 8-9 level.
Set when TX VDD is below the bytes 10-11 level.
Set when Laser Diode Current exceeds the bytes 16-17 level.
Description of Fields
JDSU Product Specification 21111542-001
JSH-42L3AD3-5, JSH-42L3AD3-5G
LW 4x/2x/1x FC SFP with DDM
JSH-42L3AD3-20
Page 35 of 45