JSH-42L3AD3-5G JDSU [JDS Uniphase Corporation], JSH-42L3AD3-5G Datasheet - Page 24

no-image

JSH-42L3AD3-5G

Manufacturer Part Number
JSH-42L3AD3-5G
Description
LW 4x/2x/1x FC SFP with DDM
Manufacturer
JDSU [JDS Uniphase Corporation]
Datasheet
JSH-42L3AD3-5, JSH-42L3AD3-5G
JSH-42L3AD3-20
LW 4x/2x/1x FC SFP with DDM
SFF 8472 Monitored Values
JDSU Product Specification 21111542-001
Page 24 of 45
Received Optical Power Meter Dynamic Range
Received Optical Power Meter Accuracy
Transmitted Optical Power Meter Dynamic Range
Transmitted Optical Power Meter Accuracy
Laser Bias Current Meter Dynamic Range
Laser Bias Current Meter Accuracy
Power Supply Voltage Meter Dynamic Range
Power Supply Voltage Meter Accuracy
Transceiver Temperature Meter Dynamic Range
Transceiver Temperature Meter Accuracy
1. Actual optical power incident on the receiver. This range, when coupled with the accuracy specified means that the power meter
2. When transceiver is operated within its specified temperature and power supply voltage dynamic operating ranges.
3. When optical input power is within the optical power meter specified dynamic operating range.
can read from -18 dBm to +3 dBm when input optical power is in the range -16 dBm to +1 dBm.
Parameter
-0.90
-0.10
-2.0
-2.0
Min
-20
4.0
2.8
-40
-9
-3
+0.90
Max
+1.0
+2.0
+2.0
0.10
-1.0
100
4.5
90
+3
Units
dBm
dBm
mA
mA
dB
dB
°C
°C
V
V
OCTOBER 2008
Notes
2,3
1
2
2
2
2
2
2
2
2