LA100-P LEM, LA100-P Datasheet - Page 2

no-image

LA100-P

Manufacturer Part Number
LA100-P
Description
Current Transducer LA 100-P
Manufacturer
LEM
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LA100-P
Manufacturer:
LEM
Quantity:
500
Part Number:
LA100-P
Quantity:
5 510
Part Number:
LA100-P
Manufacturer:
LEM
Quantity:
20 000
Company:
Part Number:
LA100-P
Quantity:
1 000
Company:
Part Number:
LA100-P
Quantity:
140
Part Number:
LA100-P/SP11
Manufacturer:
LEM
Quantity:
134
Part Number:
LA100-P/SP2
Manufacturer:
LEM
Quantity:
726
Part Number:
LA100-P/SP4
Manufacturer:
LEM
Quantity:
334
Company:
Part Number:
LA100-P/SP50
Quantity:
2 000
Company:
Part Number:
LA100-P/SP50
Quantity:
2 000
Company:
Part Number:
LA100-P/SP50 Z
Quantity:
1 000
Dimensions LA 100-P
Mechanical characteristics
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
Bottom view
Standard 00
or N
Front view
General tolerance
Primary through-hole
Fastening & connection of secondary
Recommended PCB hole
°
SP ..
(in mm. 1 mm = 0.0394 inch)
swiss
made
Year
± 0.2 mm
12.7 x 7 mm
3 pins
0.63 x 0.56 mm
0.9 mm
Week
Remarks
I
Temperature of the primary conductor should not exceed
100°C.
Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
S
is positive when I
Secondary terminals
Terminal + : supply voltage + 12 .. 15 V
Terminal - : supply voltage - 12 .. 15 V
Terminal M : measure
Connection
P
flows in the direction of the arrow.
Left view

Related parts for LA100-P