LA100-S/SP1 LEM [LEM], LA100-S/SP1 Datasheet

no-image

LA100-S/SP1

Manufacturer Part Number
LA100-S/SP1
Description
Current Transducer LA 100-S/SP1
Manufacturer
LEM [LEM]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LA100-S/SP1
Manufacturer:
STANLEY
Quantity:
1 898
Current Transducer LA 100-S/SP1
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
I
R
I
K
V
I
V
X
I
I
t
di/dt
f
T
T
R
m
Notes :
LEM Components
PN
P
SN
C
O
OT
r
A
S
C
d
M
N
G
L
S
Electrical data
Accuracy - Dynamic performance data
General data
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 min
Overall accuracy @ I
Linearity
Offset current @ I
Thermal drift of I
Response time
di/dt accurately followed
Frequency bandwidth (- 1 dB)
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ T
Mass
Standards
1)
2)
With a di/dt of 50 A/µs
A list of corresponding tests is available.
with ± 15 V
2)
O
1)
P
@ 90 % of I
= 0, T
PN,
T
A
A
= 25°C
= 25°C
@ ± 100 A
@ ± 200 A
PN
A
= 70°C
- 10 °C .. + 70°C
max
max
100
0 .. ± 200
50
1 : 2000
± 15
22 + I
3
± 0.5
< 0.1
< 1
> 50
DC .. 150
- 10 .. + 70
- 25 .. + 85
85
65
EN 50178
R
± 0.2
0
0
Typ
M min
S
R
± 0.1
± 0.4
Max
180
M max
50
A/µs
kHz
m A
m A
m A
m A
k V
µs
°C
°C
%
%
A
A
V
g
I
Features
Special features
Advantages
Applications
PN
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0.
I
K
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
P
N
= 0 .. ± 200 A
= 1 : 2000
=
100 A
w w w.lem.com
991015/5

Related parts for LA100-S/SP1

LA100-S/SP1 Summary of contents

Page 1

Current Transducer LA 100-S/SP1 For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data I Primary nominal r.m.s. current PN I Primary ...

Page 2

Dimensions LA 100-S/SP1 Front view Top view Mechanical characteristics General tolerance Fastening Primary through-hole Connection of secondary LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. (in mm ...