ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 19.
Parameter
Storage Temperature Range (T
Ambient Operating Temperature
Supply Voltages (V
Input Voltage (V
Output Voltage (V
Average Output Current per Pin
Common-Mode Transients
1
2
3
4
Table 20. Maximum Continuous Working Voltage Supporting 50-Year Minimum Lifetime
Parameter
AC Voltage, Bipolar Waveform
AC Voltage, Unipolar Waveform
DC Voltage
1
. Common-mode transients exceeding the absolute maximum slew rate may
Each voltage is relative to its respective ground.
V
given channel, respectively. See the PCB Layout section.
See
Refers to the continuous voltage magnitude imposed across the isol
cause latch-up or permanent damage.
DDI
Range (T
Basic Insulation
Reinforced Insulation
Basic Insulation
Reinforced Insulation
and V
Figure 6
DDO
A
for maximum rated current values for various temperatures.
)
refer to the supply voltages on the input and output sides of a
IA
, V
OA
DD1
IB
, V
, V
, V
OB
IC
ISO
, V
, V
)
OC
1
ID
4
, V
, V
SEL
OD
ST
3
)
)
)
1, 2
1, 2
Max
424
600
353
600
353
Rating
−55°C to +150°C
−40°C to +105°C
−0.5 V to +7.0 V
−0.5 V to V
−0.5 V to V
−10 mA to +10 mA
−100 kV/μs to +100 kV/μs
DDI
DDO
+ 0.5 V
Unit
V peak
V peak
V peak
V peak
V peak
+ 0.5 V
ation barrier. See the
Rev. B | Page 11 of 28
Applicable Certification
All certifications, 50-year operation
Working voltage per IEC 60950-1
Working voltage per IEC 60950-1
Working voltage per IEC 60950-1
Working voltage per IEC 60950-1
ADuM5401/ADuM5402/ADuM5403/ADuM5404
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION