KSZ8842-16MBL-EVAL MICREL [Micrel Semiconductor], KSZ8842-16MBL-EVAL Datasheet - Page 97

no-image

KSZ8842-16MBL-EVAL

Manufacturer Part Number
KSZ8842-16MBL-EVAL
Description
2-Port Ethernet Switch with Non-PCI Interface
Manufacturer
MICREL [Micrel Semiconductor]
Datasheet
Bank 47 PHY1 Special Control/Status Register (0x02): P1PHYCTRL
This register contains the control and status information of PHY1.
Bank 47 PHY2 LinkMD Control/Status (0x04): P2VCT
This register contains the LinkMD control and status information of PHY 2.
Micrel, Inc.
Bit
15-6
5
4
3
2
1
0
Bit
15
14-13
12
11-9
8-0
October 2007
Default
0x000
0
0
0
1
0
0
Default
0
(Self-Clear)
0x0
-
0x0
0x000
R/W
RO
RO
RO
RW
RW
RW
RW
R/W
RW
RO
RO
RO
RO
Description
Reserved
Polarity Reverse (polrvs)
1 = polarity is reversed.
0 = polarity is not reversed.
MDI-X Status (mdix_st)
1 = MDI
0 = MDI-X
Force Link (force_lnk)
1 = force link pass.
0 = normal operation.
Power Saving (pwrsave)
1 = disable power saving.
0 = enable power saving.
Remote (Near-End) Loopback (rlb)
1 = perform remote loopback at Port 1's PHY
(RXP1/RXM1 -> TXP1/TXM1, see Figure 16)
0 = normal operation
Reserved
Description
Vct_enable
1 = the cable diagnostic test is enabled. It is
self-cleared after the VCT test is done.
0 = it indicates the cable diagnostic test is
completed and the status information is valid
for read.
Vct_result
[00] = normal condition.
[01] = open condition detected in the cable.
[10] = short condition detected in the cable.
[11] = cable diagnostic test failed.
Vct 10M Short
1 = Less than 10m short.
Reserved
Vct_fault_count
Distance to the fault. The distance is
approximately 0.4m*vct_fault_count.
97
Bit is same as:
Bank 49 0x04 bit 13
Bank 49 0x04 bit 7
Bank 49 0x00 bit 11
Bank 49 0x00 bit 10
Bank 49 0x00 bit 9
Bit is same as:
Bank 51 0x00 bit 12
Bank 51 0x00 bit 14-13
Bank 51 0x00 bit 15
Bank 51 0x00 bit 8-0
KSZ8842-16/32 MQL/MVL/MVLI/MBL