XC4006 XILINX [Xilinx, Inc], XC4006 Datasheet - Page 4

no-image

XC4006

Manufacturer Part Number
XC4006
Description
Logic Cell Array Family
Manufacturer
XILINX [Xilinx, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XC4006
Manufacturer:
XILINX
0
Part Number:
XC4006 PQ160CKI
Manufacturer:
XILINX
0
Part Number:
XC4006-2PC84C
Manufacturer:
XILINX
0
Part Number:
XC4006-2PQ160
Manufacturer:
XILINX
Quantity:
513
Part Number:
XC4006-2PQ160
Manufacturer:
XILINX
0
Part Number:
XC4006-3EPQ160C
Manufacturer:
XILINX
0
Part Number:
XC4006-4PG156C
Manufacturer:
XILINX
Quantity:
1
Part Number:
XC4006-4PQ160I
Manufacturer:
XILINX
Quantity:
1 831
Part Number:
XC4006-4PQ208C
Manufacturer:
XILINX/赛灵思
Quantity:
20 000
XC4000 Logic Cell Array Family
Horizontal Longline Switching Characteristic Guidelines
Testing of the switching parameters is modeled after testing methods specified by MIL-M-38510/605. All devices are 100%
functionally tested. Since many internal timing parameters cannot be measured directly, they are derived from benchmark timing
patterns. The following guidelines reflect worst-case values over the recommended operating conditions. For more detailed, more
precise, and more up-to-date timing information, use the values provided by the XACT timing calculator and used in the simulator.
Global Buffer Switching Characteristic Guidelines
Testing of the switching parameters is modeled after testing methods specified by MIL-M-38510/605. All devices are 100%
functionally tested. Since many internal timing parameters cannot be measured directly, they are derived from benchmark timing
patterns. The following guidelines reflect worst-case values over the recommended operating conditions. For more detailed, more
precise, and more up-to-date timing information, use the values provided by the XACT timing calculator and used in the simulator.
Description
TBUF driving a Horizontal Longline (L.L.)
Description
Global Signal Distribution
I going High or Low to L.L. going High or Low,
while T is Low, i.e. buffer is constantly active
I going Low to L.L. going from resistive pull-up
High to active Low, (TBUF configured as open drain)
T going Low to L.L. going from resistive pull-up or
floating High to active Low, (TBUF configured as
open drain or active buffer with I = Low)
T going High to TBUF going inactive, not driving L.L.
T going High to L.L. going from Low to High,
pulled up by a single resistor
T going High to L.L. going from Low to High,
pulled up by two resistors
From pad through primary buffer, to any clock K
From pad through secondary buffer, to any clock K
PRELIMINARY
2-50
Symbol
Symbol
T
T
T
T
T
T
T
T
OFF
PUS
PUF
IO1
IO2
ON
PG
SG
Speed Grade
Speed Grade
All devices
XC4003
XC4005
XC4006
XC4008
XC4010
XC4013
XC4025
XC4003
XC4005
XC4006
XC4008
XC4010
XC4013
XC4025
XC4003
XC4005
XC4006
XC4008
XC4010
XC4013
XC4025
XC4003
XC4005
XC4006
XC4008
XC4010
XC4013
XC4025
XC4003
XC4005
XC4006
XC4008
XC4010
XC4013
XC4025
Device
XC4003
XC4005
XC4006
XC4008
XC4010
XC4013
XC4025
XC4003
XC4005
XC4006
XC4008
XC4010
XC4013
XC4025
Device
10.0
10.6
11.1
11.7
13.0
20.0
10.5
11.1
11.6
12.2
13.5
23.5
10.7
12.0
12.6
13.2
13.8
15.1
23.0
24.0
26.0
28.0
30.0
32.0
36.0
52.0
11.6
12.0
13.0
14.0
15.0
17.0
24.0
Max
10.0
17.0
10.0
11.0
18.0
Max
8.8
9.3
3.0
-6
7.8
8.0
8.2
8.6
9.0
8.8
9.0
9.2
9.6
-6
Max
15.0
16.0
16.5
10.0
20.0
10.0
10.5
11.0
11.5
12.6
20.5
20.0
22.0
24.0
26.0
28.0
32.0
48.0
10.0
11.0
12.0
13.0
15.0
22.0
Max
-5
6.2
7.0
7.5
8.0
8.5
9.5
6.7
7.5
8.0
8.5
9.0
9.0
2.0
9.0
5.8
6.0
6.2
6.6
7.0
8.0
6.8
7.0
7.2
7.6
8.0
9.0
-5
14.5
18.0
11.1
19.0
14.0
16.0
18.0
20.0
22.0
26.0
42.0
10.0
11.0
13.0
20.0
Max
14.5
15.7
4.4
Max
5.5
6.0
6.5
7.0
7.5
5.0
6.0
6.5
7.0
7.5
8.0
7.2
8.0
8.5
9.0
9.5
1.8
7.0
8.0
9.0
-4
5.1
5.5
5.7
6.1
6.5
7.5
6.3
6.7
6.9
7.3
7.7
8.7
-4
Units
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns

Related parts for XC4006