M29W320EB NUMONYX [Numonyx B.V], M29W320EB Datasheet - Page 21

no-image

M29W320EB

Manufacturer Part Number
M29W320EB
Description
32 Mbit (4Mbx8 or 2Mbx16, Uniform Parameter Blocks, Boot Block) 3V supply Flash memory
Manufacturer
NUMONYX [Numonyx B.V]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W320EB
Manufacturer:
ST
Quantity:
8 985
Part Number:
M29W320EB
Quantity:
5 000
Part Number:
M29W320EB
Manufacturer:
ST
0
Part Number:
M29W320EB-70
Manufacturer:
ST
0
Part Number:
M29W320EB-70N6
Manufacturer:
ST
Quantity:
8 995
Part Number:
M29W320EB-70N6
Quantity:
13
Part Number:
M29W320EB-70N6
Manufacturer:
NUMONYX
Quantity:
6 707
Part Number:
M29W320EB-70N6
Manufacturer:
ST
0
Part Number:
M29W320EB-70N6
Manufacturer:
MICRON/美光
Quantity:
20 000
Part Number:
M29W320EB-70N6-L
Manufacturer:
ST
0
Part Number:
M29W320EB-70N6E
Manufacturer:
ST
0
M29W320ET, M29W320EB
4.3
4.4
Read CFI Query command
The Read CFI Query Command is used to read data from the Common Flash Interface
(CFI) memory Area. This command is valid when the device is in the Read Array mode, or
when the device is in Auto Select mode.
One Bus Write cycle is required to issue the Read CFI Query Command. Once the
command is issued subsequent Bus Read operations read from the Common Flash
Interface memory Area.
The Read/Reset command must be issued to return the device to the previous mode (the
Read Array mode or Auto Select mode). A second Read/Reset command would be needed
if the device is to be put in the Read Array mode from Auto Select mode.
See
Table 26
Interface (CFI) memory area.
Program command
The Program command can be used to program a value to one address in the memory array
at a time. The command requires four Bus Write operations, the final write operation latches
the address and data, and starts the Program/Erase Controller.
If the address falls in a protected block then the Program command is ignored, the data
remains unchanged. The Status register is never read and no error condition is given.
During the program operation the memory will ignore all commands. It is not possible to
issue any command to abort or pause the operation. After programming has started, Bus
Read operations output the Status register content. See
details. Typical program times are given in
After the program operation has completed the memory will return to the Read mode, unless
an error has occurred. When an error occurs Bus Read operations will continue to output
the Status register. A Read/Reset command must be issued to reset the error condition and
return to Read mode.
Note that the Program command cannot change a bit set at ’0’ back to ’1’. One of the Erase
Commands must be used to set all the bits in a block or in the whole memory from ’0’ to ’1’.
Appendix B: Common Flash Interface
and
Table 27
for details on the information contained in the Common Flash
Table 6
(CFI),
Table
22,
Section 5: Status register
Table
23,
Table
Command interface
24,
Table
for more
25,
21/63