X9269 Xicor, X9269 Datasheet - Page 10

no-image

X9269

Manufacturer Part Number
X9269
Description
Dual Digitally-Controlled Potentiometers
Manufacturer
Xicor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
X9269
Quantity:
80
Part Number:
X9269TS
Manufacturer:
Intersil
Quantity:
2
Part Number:
X9269TS24
Manufacturer:
XICOR
Quantity:
1 377
Part Number:
X9269TS24Z
Manufacturer:
Intersil
Quantity:
1 000
Part Number:
X9269US
Manufacturer:
XICOR
Quantity:
20 000
X9269
DEVICE DESCRIPTION
Instructions
Four of the nine instructions are three bytes in length.
These instructions are:
– Read Wiper Counter Register – read the current
– Write Wiper Counter Register – change current
– Read Data Register – read the contents of the
– Write Data Register – write a new value to the
The basic sequence of the three byte instructions is
illustrated in Figure 4. These three-byte instructions
exchange data between the WCR and one of the Data
Registers. A transfer from a Data Register to a WCR is
essentially a write to a static RAM, with the static RAM
controlling the wiper position. The response of the
wiper to this action will be delayed by t
from the WCR (current wiper position), to a Data
Register is a write to nonvolatile memory and takes a
minimum of t
between one of the four potentiometers and one of its
associated registers; or it may occur globally, where the
transfer occurs between all potentiometers and one
associated register
Four instructions require a two-byte sequence to
complete. These instructions transfer data between the
host and the X9269; either between the host and one of
the data registers or directly between the host and the
Wiper Counter Register. These instructions are:
REV 1.1.11 2/17/03
wiper position of the selected potentiometer,
wiper position of the selected potentiometer,
selected Data Register;
selected Data Register.
WR
to complete. The transfer can occur
WRL
. A transfer
www.xicor.com
– XFR Data Register to Wiper Counter Register –
– XFR Wiper Counter Register to Data Register –
– Global XFR Data Register to Wiper Counter
– Global XFR Wiper Counter Register to Data
INCREMENT/DECREMENT COMMAND
The final command is Increment/Decrement (Figure 5
and 6). The Increment/Decrement command is different
from the other commands. Once the command is
issued and the X9269 has responded with an
acknowledge, the master can clock the selected wiper
up and/or down in one segment steps; thereby,
providing a fine tuning capability to the host. For each
SCL clock pulse (t
selected wiper will move one resistor segment towards
the R
while SDA is LOW, the selected wiper will move one
resistor segment towards the R
See Instruction format for more details.
This transfers the contents of one specified Data
Register to the associated Wiper Counter Register.
This transfers the contents of the specified Wiper
Counter Register to the specified associated Data
Register.
Register – This transfers the contents of all specified
Data Registers to the associated Wiper Counter Reg-
isters.
Register – This transfers the contents of all Wiper
Counter Registers to the specified associated Data
Registers.
H
terminal. Similarly, for each SCL clock pulse
Characteristics subject to change without notice.
HIGH
) while SDA is HIGH, the
L
terminal.
10 of 25