X9316 Xicor, X9316 Datasheet

no-image

X9316

Manufacturer Part Number
X9316
Description
E 2 POT Nonvolatile Digital Potentiometer
Manufacturer
Xicor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X9316WS
Manufacturer:
XICOR
Quantity:
20 000
Company:
Part Number:
X9316ZP
Quantity:
140
Low Noise, Low Power, 32 Taps
FEATURES
• Low Micropower CMOS
• Low Noise
• 31 Resistive Elements
• 32 Wiper Tap Points
• 100 Year Wiper Position Data Retention
• X9316Z = 1K
• X9316W = 10K
• Packages
FUNCTIONAL DIAGRAM
E2POT™ is a trademark of Xicor, Inc.
7000-1.5 7/16/97 T6/C0/D6 SH
Xicor, Inc. 1994, 1995, 1996 Patents Pending
—V
—Active Current, 50 A (Increment) Max
—Standby Current, 400 A (Store) Max
—Temperature Compensated
— 20% End to End Resistance Range
—–5V to +5V
—Wiper Positioned via Three-Wire Interface
—Similar to TTL Up/Down Counter
—Wiper Position Stored in Nonvolatile
—14-Lead PDIP
—14-Lead SOIC
Memory and Recalled on Power-Up
CC
= 3V to 5.5V
V +
V–
V
V
CC
SS
U/D
INC
CS
NONVOLATILE
STORE AND
CIRCUITRY
E
COUNTER
CONTROL
UP/DOWN
MEMORY
RECALL
2
5-BIT
5-BIT
POT™ Nonvolatile Digital Potentiometer
DECODER
POSITION
THIRTY-
WIPER
X9316
TWO
ONE
OF
1
DESCRIPTION
The Xicor X9316 is a solid state “micropower” nonvolatile
potentiometer and is ideal for digitally controlled resis-
tance trimming in battery-powered systems.
The X9316 is a resistor array composed of 31 resistive
elements. Between each element and at either end are
tap points accessible to the wiper element. The position
of the wiper element is controlled by the CS, U/D, and
INC inputs. The position of the wiper can be stored in
nonvolatile memory and then be recalled upon a subse-
quent power-up operation.
The resolution of the X9316 is equal to the maximum
resistance value divided by 31. As an example, for the
X9316W (10K ) each tap point represents 323 .
All Xicor nonvolatile memories are designed and tested
for applications requiring extended endurance and data
retention.
CMOS SWITCH
Characteristics subject to change without notice
RESISTOR
ARRAY
V
V
V
H
L
W
7000 FRM F01

Related parts for X9316

X9316 Summary of contents

Page 1

... The Xicor X9316 is a solid state “micropower” nonvolatile potentiometer and is ideal for digitally controlled resis- tance trimming in battery-powered systems. The X9316 is a resistor array composed of 31 resistive elements. Between each element and at either end are tap points accessible to the wiper element. The position of the wiper element is controlled by the CS, U/D, and INC inputs ...

Page 2

... The device is selected when the CS input is LOW. The current counter value is stored in nonvolatile memory when CS is returned HIGH while the INC input is also HIGH. After the store operation is complete, the X9316 will be placed in the low power standby mode until the device is selected once again. ...

Page 3

... When power is restored, the contents of the memory are recalled and the counter is reset to the value last stored. Operation Notes The system may select the X9316, move the wiper and deselect the device without having to store the latest wiper position in nonvolatile memory. The wiper move- ment is performed as described above ...

Page 4

... X9316W...........................................................10V Lead Temperature (Soldering 10 seconds) ....... 300 C Wiper Current..................................................... 1mA ANALOG CHARACTERISTICS Electrical Characteristics End-to-End Resistance Tolerance .................... 20% Power Rating X9316Z ........................................................16mW X9316W.......................................................10mW Wiper Current ........................................... 1mA Max. Typical Wiper Resistance ...................... 100 at 1mA Typical Noise ............................ < –140dB Hz Ref: 1V Resolution Resistance .............................................................3% Linearity ...

Page 5

... STANDARD PARTS Part Number Maximum Resistance X9316Z X9316W Notes: (4) Typical values are for and nominal supply voltage. A (5) This parameter is periodically sampled and not 100% tested. Max. Supply Voltage +70 C X9316 +85 C 7000 FRM T02 Limits (4) Min. Typ. Max. 50 400 1 400 ...

Page 6

... X9316 A.C. CONDITIONS OF TEST Input Pulse Levels Input Rise and Fall Times Input Reference Levels A.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified) Symbol Parameter INC Setup Cl t INC HIGH to U/D Change lD t U/D to INC Setup DI t INC LOW Period lL t INC HIGH Period ...

Page 7

... X9316 TYPICAL NOISE 0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 -110 -120 -130 -140 -150 TYPICAL RTOTAL vs. TEMPERATURE 10000 9800 9600 9400 9200 9000 8800 8600 8400 8200 8000 -55 -45 -35 - 100 110 120 Frequency (KHz) - ...

Page 8

... X9316 TYPICAL TOTAL RESISTANCE TEMPERATURE COEFFICIENT 0 -50 -100 -150 PPM -200 -250 -300 -350 -55 -45 -35 -25 -15 TYPICAL WIPER RESISTANCE 800 700 600 500 400 300 200 100 Temperature Tap 105 115 ...

Page 9

... X9316 TYPICAL ABSOLUTE % ERROR PER TAP POSITION 40.0% 30.0% 20.0% 10.0% 0.0% -10.0% -20.0% -30.0% -40. TYPICAL RELATIVE % ERROR PER TAP POSITION 20.0% 15.0% 10.0% 5.0% 0.0% -5.0% -10.0% -15.0% -20. Tap Tap ...

Page 10

... X9316 PACKAGING INFORMATION 14-LEAD PLASTIC DUAL IN-LINE PACKAGE TYPE P PIN 1 INDEX HALF SHOULDER WIDTH ON ALL END PINS OPTIONAL SEATING PLANE 0.150 (3.81) 0.125 (3.18) 0.110 (2.79) 0.090 (2.29) 0.015 (0.38) MAX. TYP . 0.010 (0.25) NOTE: 1. ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 2. PACKAGE DIMENSIONS EXCLUDE MOLDING FLASH 0.720 (18.29) 0.640 (16.26) PIN 1 0 ...

Page 11

... X9316 PACKAGING INFORMATION 14-LEAD PLASTIC SMALL OUTLINE GULL WING PACKAGE TYPE S PIN 1 INDEX PIN 1 0.014 (0.35) 0.020 (0.51) (4X) 7 0.050 (1.27) 0.010 (0.25 0.020 (0.50) 0 – 8 0.016 (0.410) 0.037 (0.937) NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 0.150 (3.80) 0.158 (4.00) 0.336 (8.55) 0.345 (8.75) 0.004 (0.10) 0.010 (0.25) 0.250" 0.0075 (0.19) 0.010 (0.25) ...

Page 12

... A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system affect its safety or effectiveness. X9316X Blank = 4 ...