DMS-20LCD-4 MURATA-PS [Murata Power Solutions Inc.], DMS-20LCD-4 Datasheet

no-image

DMS-20LCD-4

Manufacturer Part Number
DMS-20LCD-4
Description
Manufacturer
MURATA-PS [Murata Power Solutions Inc.]
Datasheet
FEATURES
SIMPLIFIED SCHEMATIC DIAGRAM
Super-low loop drop: 1.8V typical, 2.0V max.
Self-powered, no separate supply required
Unipolar, Bipolar, and Positive Reading Models
Subminiature package—Less than 0.90” behind-the-
panel depth
Large, 0.37"/9.4mm high, sunlight-viewable
LCD display
Non-interacting gain (span) and offset (zero) 20-turn
potentiometers
DIP-switch selectable range and decimal points
Hundreds of different input/readout combinations
Vibration-resistant package; reliable screw-terminal
input connections
www.murata-ps.com/rohs
For full details go to
 
+5V
R3
REFERENCE
CONVERTER
BAND-GAP
ADJUST
CIRCUIT
DC/DC
ZERO
R7
–5V
ADJUST
GAIN
www.murata-ps.com
priced, 4-20mA input, 3½ digit LCD-display process monitors: 1.8V typical, 2.0V max. This
super-low drop means its nominal loop resistance (burden) is less than 100 Ohms! All op-
erating power is derived solely from the 4-20mA loop current—no separate power source
is required! The simple 2-wire hookup allows the DMS-20LCD-4/20 Series to be connected
anywhere in the loop
switch featuring vibration-resistant, gold-plated contacts—there are no jumpers or solder
gaps to ever open or close. Both gain (span) and offset (zero) adjustments are performed
with precision, 20-turn potentiometers. Three different models are available for unipolar,
bipolar, and positive display reading applications. The DMS-20LCD-4/20’s DIP switch and
adjustment potentiometers can accommodate literally hundreds of different input-current/
output-reading combinations. And, connections to the current loop are made via a reliable,
two-position, screw-type terminal block.
high digits, LCD display that can be read in virtually all lighting conditions—including direct
sunlight. An optional bezel assembly, featuring screw fasteners and a rubber seal, simplifies
panel mounting and provides excellent resistance to environmental dust and moisture.
All these outstanding features combine to make the DMS-20LCD-4/20 Series the perfect
meters for OEM 4-20mA current-loop process monitoring instrumentation.
The DMS-20LCD-4/20 Series produces the lowest loop voltage-drop of any comparably
The DMS-20LCD-4/20 Series’ subminiature package houses a large, 0.37"/9.4mm
All decimal-point and range-change selections are made via a six-position DIP
1
1
1
3½ DIGIT A/D
CONVERTER
1
2
2
2
CURRENT TO
CONVERTER
2
VOLTAGE
4-20mA Input Loop-Powered Ultra-Low 1.8V Loop Drop
3
3
3
ON
ON
ON
3
4
4
4
5
5
5
DMS-20LCD-4/20 Series
DATA
6
6
6
Technical enquiries email: sales@murata-ps.com, tel:
DIP SWITCHES
3½ Digit LCD Display Process Monitors
DP1
DP2
LOOP INPUT
MPM_DMS20LCD-420.B02 Page 1 of 6
+
1
TB1
DP3
2
+1 508 339 3000

Related parts for DMS-20LCD-4

DMS-20LCD-4 Summary of contents

Page 1

... Ohms! All op- erating power is derived solely from the 4-20mA loop current—no separate power source is required! The simple 2-wire hookup allows the DMS-20LCD-4/20 Series to be connected anywhere in the loop All decimal-point and range-change selections are made via a six-position DIP switch featuring vibration-resistant, gold-plated contacts— ...

Page 2

... Case Material Weight 0.6 ounces (17 grams) The DMS-20LCD-4/20, using any of the DIP-switch settings described above, can withstand overcurrents, including those resulting from accidental reverse- polarity connections ±40mA without sustaining any damage. Because DATEL's DMS-4/20 loop-powered meters employ active circuitry to convert the loop current into a voltage, the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4-to-20mA current range. Listed impedance specifi ...

Page 3

... Example #3 below illustrates this concept. Please contact DATEL if there is any doubt as to whether or not the DMS-20LCD-4/20P can be configured for your display readings requirements. www.murata-ps.com DMS-20LCD-4/20 Series 3½ Digit LCD Display Process Monitors 20mA and adjust R7 so the display reads "1.00". Apply 4mA and verify that the display reads " ...

Page 4

... The first step when configuring the DMS-20LCD-4/20P for the first time, or when selecting a new range set R3 fully counterclockwise and R7 fully clockwise (roughly 22 turns) to their minimum offset/minimum span posi- tions, respectively. The next step is to calculate the required display differential-reading; this is accomplished by subtracting the desired 4mA display reading from the desired 20mA display reading, disregarding decimal points ...

Page 5

... ONLY WHEN USING OPTIONAL BEZEL ASSEMBLY 4-20mA Input Loop-Powered Ultra-Low 1.8V Loop Drop PROGRAMMABLE LOGIC CONTROLLER – (TB1-1) 4-20mA 4-20mA – (TB1-2) +24V Shown for illustrative purposes only, may not be present in all applications Figure 2. Typical DMS-20LCD-4/20 Connection Diagram 0.187 (4.75) 1.280 (32.51) 0.838 (21.29) 0.145 (3.68) 0.116 (2.95) www.murata-ps.com DMS-20LCD-4/20 Series 3½ ...

Page 6

... USA: Canada: UK: France: Germany: Japan: 11/25/08 China: © 2008 Murata Power Solutions, Inc. Singapore: www.murata-ps.com DMS-20LCD-4/20 Series 3½ Digit LCD Display Process Monitors 0.90 (22.9) 0.040 (1.02) ® 0.80 (20.3) 0.88 (22.4) Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps ...