DSD-40PC-1-GS-C MURATA-PS [Murata Power Solutions Inc.], DSD-40PC-1-GS-C Datasheet
DSD-40PC-1-GS-C
Related parts for DSD-40PC-1-GS-C
DSD-40PC-1-GS-C Summary of contents
Page 1
FEATURES Precision, autozeroing, factory-calibrated A/D converter Scientific-grade accuracy, ±2 counts Miniature size: 2.17" x 0.92" x 0.56" 55mm x 23mm x 14mm Large (0.52"/13.2mm) LED display Choice of red, green or yellow colors High-intensity or low-power red LED's optional Single ...
Page 2
Performance/Functional Specifications Typical +25°C and supply voltage = +5V using the single-ended input A circuit, unless otherwise noted. Analog Inputs Min. Full Scale Input Range: DMS-40PC-1 – DMS-40PC-2 – DMS-40PC-3 – Input Impedence: – DMS-40PC-1 100 DMS-40PC-2, ...
Page 3
DISPLAY HOLD (Pin 9): For normal operation, this pin should be left open. To hold the meter’s last reading and display it continuously, tie pin 9 to ground (pin 3, 5V RETURN). 5. Decimal Point Placement: The location of ...
Page 4
APPLICATIONS 2. Differential Input Configurations: Differential inputs can also be measured with DMS-40PC meters as shown in the circuit of Figure 3. Differential inputs must also originate from power supplies that have a common ground with the meter’s 5V RETURN ...
Page 5
APPLICATIONS 5. Engineering Scaling and Input Attenuation: In many applications, the input signal must be scaled, or divided down, before being applied to the DMS-40PC. In some situations, the input signal exceeds the full-scale range of the meter, and in ...
Page 6
MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES DEC ±0.02 (±0.51 DEC ±0.010 (±0.254) LEAD DIMENSIONS: 0.025 (0.635) x 0.025 (0.635) NOMINAL RECOMMENDED PC BOARD FINISHED HOLE DIAMETER: 0.042 ±0.003 (1.067 ±0.076) CALIBRATION POTENTIOMETER HOLE LOCATION PIN 1 (USE ...