DS1775R/TR1 DALLAS [Dallas Semiconductor], DS1775R/TR1 Datasheet

no-image

DS1775R/TR1

Manufacturer Part Number
DS1775R/TR1
Description
SOT23-5 Digital Thermometer and Thermostat
Manufacturer
DALLAS [Dallas Semiconductor]
Datasheet
FEATURES
§ Temperature measurements require no
§ Measures temperatures from –55 C to
§ Thermometer accuracy is 2.0 C
§ Thermometer resolution is configurable from
§ Thermostat settings are user definable
§ Data is read from/written to via a 2–wire
§ Wide power supply range (2.7V – 5.5V)
§ Software compatible with DS75 2–Wire
§ Space–conscious SOT23–5 package with
ORDERING INFORMATION
DESCRIPTION
The DS1775 SOT23-5 Digital Thermometer and Thermostat provides temperature readings which
indicate the temperature of the device. Thermostat settings and temperature readings are all
communicated to/from the DS1775 over a simple 2–wire serial interface. No additional components are
required; the device is truly a “temperature–to–digital” converter.
For applications that require greater temperature resolution, the user can adjust the readout resolution
from 9 to 12 bits. This is particularly useful in applications where thermal runaway conditions must be
detected quickly.
The open–drain thermal alarm output, O.S., becomes active when the temperature of the device exceeds a
user–defined temperature T
configurable by the user. The device can also be configured in the interrupt or comparator mode, to
customize the method which clears the fault condition.
www.dalsemi.com
external components
+125 C. Fahrenheit equivalent is –67 F to
257 F
9 to 12 bits (0.5 C to 0.0625 C resolution)
serial interface
Thermal Watchdog in thermometer mode
low thermal time constant
DS1775R/TRL
DS1775R/TR1
DS1775R/TR2
DS1775R/TR3
Part Number
* "R" denotes SOT 23-5 Package
OS
. The number of consecutive faults required to set O.S. active is
Address
000
001
010
011
1 of 13
PIN ASSIGNMENT
PIN DESCRIPTION
GND
SCL
SDA
V
O.S.
DD
DS1775R/TR4
DS1775R/TR5
DS1775R/TR6
DS1775R/TR7
Part Number
GND
SCL
O.S.
SOT23-5 Digital Thermometer
DS1775R
SOT23-5
1
2
3
Ground
2–Wire Serial Clock
2–Wire Serial Data Input/Output
Power Supply Voltage
Thermostat Output Signal
4
5
Address
100
101
110
111
V
SDA
DD
and Thermostat
PRODUCT PREVIEW
PRELIMINARY
DS1775
102299

Related parts for DS1775R/TR1

DS1775R/TR1 Summary of contents

Page 1

... Thermal Watchdog in thermometer mode § Space–conscious SOT23–5 package with low thermal time constant ORDERING INFORMATION Part Number DS1775R/TRL DS1775R/TR1 DS1775R/TR2 DS1775R/TR3 * "R" denotes SOT 23-5 Package DESCRIPTION The DS1775 SOT23-5 Digital Thermometer and Thermostat provides temperature readings which indicate the temperature of the device. Thermostat settings and temperature readings are all communicated to/from the DS1775 over a simple 2– ...

Page 2

As a digital thermometer, the DS1775 is software compatible with the DS75 2–Wire Thermal Watchdog. The DS1775 is assembled in a compact SOT23–5 package allowing for low–cost thermal monitoring/control in space–constrained applications. The low thermal mass allows for time constants ...

Page 3

O.S. output will become active only after the measured temperature exceeds the respective trippoint a consecutive number of times; the number of consecutive conversions beyond the limit to generate an O.S. is programmable. The power–up state of the DS1775 ...

Page 4

The resolution of the temperature conversion is configurable (9, 10, 11 bits), with 9–bit readings the default state. This equates to a temperature resolution of 0.5 C, 0.25 C, 0.125 C, or 0.0625 C. Following each conversion, thermal ...

Page 5

O.S. OUTPUT TRANSFER FUNCTION Figure 2 Regardless of the mode chosen, the O.S. output is open–drain and the active state is set in the configuration register. The power–up default is active low. Refer to the “OPERATION–Programming” section for instructions in ...

Page 6

The only exception is at power–up, in which case the pointer will always be set to 00h, the temperature register. The pointer address must always proceed data in writing to a register, regardless of which address is currently selected. Please ...

Page 7

Thermometer Resolution Configuration Table Thermometer Resolution Thermostat Setpoints Programming The thermostat registers (T OS accessed by setting the DS1775 data pointer to the 03h location, and to the 02h ...

Page 8

Data transfer may be initiated only when the bus is not busy. During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in the data line while the clock line is high will be ...

Page 9

Figure 5 details how data transfer is accomplished on the two–wire bus. Depending upon the state of the R/W bit, two types of data transfer are possible: 1. Data transfer from a master transmitter to a slave receiver. The first ...

Page 10

SERIAL COMMUNICATION WITH DS1775 Figure DS1775 102299 ...

Page 11

ABSOLUTE MAXIMUM RATINGS* Voltage on VDD, Relative to Ground Voltage on any other pin, Relative to Ground Operating Temperature Storage Temperature Soldering Temperature * This is a stress rating only and functional operation of the device at these or any ...

Page 12

AC ELECTRICAL CHARACTERISTICS: 2–WIRE INTERFACE PARAMETER SCL clock frequency Bus free time between a STOP and START condition Hold time (repeated) START condition LOW period of SCL HIGH period of SCL Set-up time for a repeated START Data hold time ...

Page 13

TIMING DIAGRAMS Figure DS1775 102299 ...

Related keywords