UPD65 NEC [NEC], UPD65 Datasheet - Page 23

no-image

UPD65

Manufacturer Part Number
UPD65
Description
4-BIT SINGLE-CHIP MICROCONTROLLER FOR INFRARED REMOTE CONTROL TRANSMISSION
Manufacturer
NEC [NEC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD65002G-052
Manufacturer:
PANASONIC
Quantity:
2 809
Part Number:
UPD65002G-052
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD65003C-073
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD65004C048
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD65005C280
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD65005C280
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD65005CF-192
Manufacturer:
ST
Quantity:
5 172
Part Number:
UPD65005CF-192
Manufacturer:
NEC
Quantity:
2 000
Part Number:
UPD65005CF-192
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD65006C-096
Manufacturer:
NEC
Quantity:
20 000
Part Number:
UPD65006G-220
Manufacturer:
BEL
Quantity:
278
Part Number:
UPD65006GF-302-3B8
Manufacturer:
VISHAY
Quantity:
11
Part Number:
UPD65012C286
Manufacturer:
NEC
Quantity:
6 231
Part Number:
UPD65012C378
Manufacturer:
NEC
Quantity:
1 000
Part Number:
UPD65012C378
Manufacturer:
NEC
Quantity:
20 000
5.2 Standby Mode Setup and Release
standby mode to be set, the status flag (F) is required to have been cleared (to 0).
instruction. If the standby mode is released, the status flag (F) is set (to 1).
mode is not set. If the release condition is not met at this time, the status flag is cleared (to 0). If the release condition
is met, the status flag remains set (to 1).
executed, the standby mode is not set. Here, also, the status flag (F) is set (to 1).
The standby mode is set with the HALT #b
The standby mode is released by the release condition specified with the reset (POC) or the operand of HALT
Even when the HALT instruction is executed in the state that the status flag (F) has been set (to 1), the standby
Even in the case when the release condition has been already met at the point that the HALT instruction is
Caution Depending on the status of the status flag (F), the HALT instruction may not be executed. Be
Example
careful about this. For example, when setting HALT mode after checking the key status with
the STTS instruction, the system does not enter HALT mode as long as the status flag (F)
remains set (to 1) thus sometimes performing an unintended operation. In this case, the
intended operation can be realized by executing the STTS instruction immediately after timer
setting to clear (to 0) the status flag.
Reset
Release condition shown in Table 5-3
Table 5-2. Addresses Executed after Standby Mode Release
STTS
MOV
STTS
HALT
Release Condition
#03H
T, #0xxH
#05H
(During this time, be sure not to execute an instruction that may set the status flag.)
#05H
Data Sheet U14380EJ2V0DS00
3
;To check the K
;To set the timer
;To clear the status flag
;To set HALT mode
b
2
b
1
b
0
B instruction for both STOP mode and HALT mode. For the
0 address
The address following the HALT instruction
I
pin status.
Address Executed after Release
PD64A, 65
23

Related parts for UPD65