nph10s C&D Technologies., nph10s Datasheet

no-image

nph10s

Manufacturer Part Number
nph10s
Description
Isolated 10w Single Output Dc/dc Converters
Manufacturer
C&D Technologies.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
nph10s2403EI
Manufacturer:
C&D
Quantity:
1 000
Part Number:
nph10s2403IC
Manufacturer:
C&DTech
Quantity:
492
Part Number:
nph10s2405EIC
Manufacturer:
C&DTech
Quantity:
530
Part Number:
nph10s2405IC
Manufacturer:
Murata Power Solutions Inc
Quantity:
135
Part Number:
nph10s2405IC
Manufacturer:
C&DTech
Quantity:
560
Part Number:
nph10s4803IC
Manufacturer:
MURATA/C&D
Quantity:
20 000
FEATURES
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
DESCRIPTION
The NPH10S series of DC/DC converters combines
ease of application with versatility. The pin pattern
is based on the popular industry standard, but two
additional pins may optionally be fitted to provide
a variety of features not commonly found on units
of this type. High efficiency enables full rating to
be achieved in a small package without heat-
sinking. Thermally protected against sustained
overload. The copper case achieves efficient heat
transfer and screening. The product range has
been recognised by Underwriters Laboratory (UL)
to UL 1950 for operational insulation, file number
E179522 applies.
www.murata-ps.com
RoHS compliant
High efficiency to 87%
Power density up to 1.5Wcm
UL 94V-0 package material
Industry standard pinout
Surge rating to 12W
Non latching current limit
1.5kV input to output isolation
Versatile control options
Continuous rating to 10W at 72ºC without
Operation to zero load
Protected against load faults
Internal over temperature protection
Uses no electrolytic capacitors
Fixed frequency
No external components required
heatsink
www.murata-ps.com/rohs
For full details go to
 
3
1. Parts ending with EiC have optional TRIM and SS pins fitted.
2. Current is quoted when output is 95% of regulated voltage.
3. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
4. For applications requiring UL1950 recognition, input voltage must not exceed 60VDC.
5. A minimum load of 10% of rating is recommended for typical applications; see application notes.
6. Absolute maximum value for 30 seconds. Prolonged application may damage the product.
SELECTION GUIDE
Order Code
NPH10S2403EiC
NPH10S2403iC
NPH10S2405EiC
NPH10S2405iC
NPH10S2412EiC
NPH10S2412iC
NPH10S2415EiC
NPH10S2415iC
NPH10S4803EiC
NPH10S4803iC
NPH10S4805EiC
NPH10S4805iC
NPH10S4812EiC
NPH10S4812iC
NPH10S4815EiC
NPH10S4815iC
INPUT CHARACTERISTICS
Parameter
Voltage range
OUTPUT CHARACTERISTICS
Parameter
Voltage set point error
Overall voltage error
Temperature coefficient
of output voltage (slope)
Deviation of output
voltage
Line regulation
Load Regulation
Ripple
ABSOLUTE MAXIMUM RATINGS
Input voltage, 24V input types
Input voltage, 48V input types
Output voltage
Output trim control
Synchronisation/shutdown control
All specifications typical at T
1
Nominal Input
Voltage
A
=25°C, nominal input voltage and rated output current unless otherwise specified.
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
V
Conditions
Continuous operation, 24V input types
Continuous operation, 48V input types
Conditions
50% load after 30 mins at nominal supply
voltage
Case temperature -40ºC to 110ºC
Load 0% - 100%
Input specified range
Over any 10ºC span within the specified
temperature range
Specified over temperature MIN-MAX
Operating voltage range, 50% load
0% - 100% rated load
rms
Voltage
Output
12.1
12.1
15.1
15.1
12.1
12.1
15.1
15.1
3.4
3.4
5.1
5.1
3.4
3.4
5.1
5.1
V
Isolated 10W Single Output DC/DC Converters
Technical enquiries - email: mk@murata-ps.com, tel:
-0.5V to 40V
-0.5V to 80V
-0.3V to controlled output voltage (operating or non-operating)
-1V to +30V
±15V relative to input return
5
Current
Output
2.94
2.94
1.96
1.96
0.83
0.83
0.67
0.67
2.94
2.94
1.96
1.96
0.83
0.83
0.67
0.67
A
6
6
Limit
Current
4
4.3
4.3
3.1
3.1
1.2
1.2
1.1
1.1
4.1
4.1
2.8
2.8
1.3
1.3
1.0
1.0
2
A
(Typ.)
NPH10S Series
Efficiency
Min.
Min.
18
36
79
79
83
83
86
86
86
86
80
80
83
83
86
86
87
87
%
KDC_NPH10SC.I02 Page 1 of 8
Capacitance
0.05
Typ.
Typ.
0.5
Max. Load
24
48
50
70
1
470
470
470
470
100
100
470
470
470
470
µF
47
47
56
56
22
22
+44 (0)1908 615232
Max.
Max.
250
0.5
2.5
0.1
0.5
36
75
1
MTTF
kHrs
279
279
275
275
259
259
243
243
317
317
312
312
291
291
272
272
ppmºC
Units
Units
mV
%
%
%
%
%
V
3

Related parts for nph10s

nph10s Summary of contents

Page 1

... Fixed frequency n No external components required n DESCRIPTION The NPH10S series of DC/DC converters combines ease of application with versatility. The pin pattern is based on the popular industry standard, but two additional pins may optionally be fitted to provide a variety of features not commonly found on units of this type. High efficiency enables full rating to be achieved in a small package without heat- sinking ...

Page 2

... Min. Typ. Max. 1500 Min. Typ. Max. -40 110 -40 125 85 110 110ºC 2.3 3.0 4.0 4.0 1.0 1 Technical enquiries - email: mk@murata-ps.com, tel: KDC_NPH10SC.I02 Page Units % V ms kHz kHz Units VDC GΩ pF Units ºC % ºC Units W W +44 (0)1908 615232 ...

Page 3

... NPH10S When the output voltage is trimmed up, output current must be derated so that the maximum output power 10W is not exceeded. Example to decrease output voltage of NPH10S4805EiC by 0.1V: SET VOLTAGE The output voltage of all units is set to 100mV above nominal, to offset resistive losses and thus assist with worst case error calculations. For the EiC versions, this allowance can be altered with a single fixed resistor, connected from the trimming pin to one of the output pins ...

Page 4

... A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The NPH10S series has been recognized by Underwriters Laboratory, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier ...

Page 5

... MPS 18R104C MPS 18R472C 100µH 1.2A 4.7µH 5.35A MPS 18R104C MPS 18R103C 100µH 1.2A 10µH 3.45A MPS 18R104C MPS 18R333C 100µH 1.2A 33µH 2.00A MPS 18R104C MPS 18R333C 100µH 1.2A 33µH 2.00A +44 (0)1908 615232 KDC_NPH10SC.I02 Page ...

Page 6

... EMC FILTERING AND SPECTRA (continued) NPH10S2403 NPH10S2412 NPH10S4803 www.murata-ps.com NPH10S Series Isolated 10W Single Output DC/DC Converters NPH10S2405 NPH10S2415 NPH10S4805 Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NPH10SC.I02 Page ...

Page 7

... EMC FILTERING AND SPECTRA (continued) NPH10S4812 www.murata-ps.com NPH10S Series Isolated 10W Single Output DC/DC Converters NPH10S4815 Technical enquiries - email: mk@murata-ps.com, tel: +44 (0)1908 615232 KDC_NPH10SC.I02 Page ...

Page 8

... Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Technical enquiries - email: mk@murata-ps.com, tel: KDC_NPH10SC.I02 Page Tube Quantity: 15 +44 (0)1908 615232 ...

Related keywords