Page 1
... FCC emissions characterization. The automated surface mount assembly is fully RoHS (Reduction of Hazardous Substances) lead-free construction and attachment. The LSM2-T/30-D12 mounts to its host carrier board via reflow-soldered PCB pads. The extraordinary efficiency means low heat and freedom from expensive, bulky heat sinks. A ...
Page 2
... Load 125 15 25 ±0.2% ±0.4% 125 15 25 ±0.2% ±0.4% Nominal line voltage, no-load/full-load conditions. LSM2-T/30-D12 efficiencies are shown at V I max Amps with Vin = 0.8 to 3.6 Volts. With V out ➆ >3.63V, input range is 7-14V. out L SM2 T 30 D12 R - ...
Page 3
... The “R” pads and the standard pads 1 and 2 are in parallel. If your application uses a standard DOSA pad layout and you cannot con- nect to these ground pads, order model LSM2-T/30-D12-C without the “R” designator. Please observe the lower Derating curves for standard, “non-R” ...
Page 4
... Short circuit shutdown begins when the output voltage degrades approximately 2% from the selected setting. www.murata-ps.com LSM2-T/30-D12 Series DOSA-SMT, 30A POL DC/DC Converters Dynamic Characteristics 60 µSec to within ±2% of final value ...
Page 5
... Output current limiting is disabled at start up to avoid overcurrent shutdown while charging external bypass capacitors. Output Adjustments The LSM2-T/30-D12 series includes a special output voltage trimming fea- ture which is fully compatible with competitive units. The output voltage may be varied using a single trim resistor from the Trim Input to Power Common. ...
Page 6
... 2.66 4.31 5.97 7.62 9.28 10.9 12.6 14.2 Load C urre nt (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 300 LFM 29.00 400 LFM 28.00 500 LFM 27.00 26.00 25.00 24.00 23.00 22.00 21.00 20.00 Natural Convection 19.00 100 LFM 18.00 200 LFM 17.00 16.00 15.00 14.00 13 ...
Page 7
... utput Current (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 300 LFM 29.00 400 LFM 28 ...
Page 8
... utput C urre nt (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 300 LFM 29.00 400 LFM 28.00 27.00 26.00 25.00 24.00 23.00 22.00 21.00 Natural Convection 100 LFM 20 ...
Page 9
... Load Current (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 29.00 28.00 27.00 26.00 25.00 Natural Convection 24.00 ...
Page 10
... Output Current (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 300 LFM 30.00 400 LFM 29.00 28.00 27.00 26.00 25.00 24.00 23.00 Natural Convection 22.00 100 LFM 21.00 200 LFM 20.00 19.00 18.00 17.00 16. ...
Page 11
... Output Current (Amps) LSM2-T/30-D12R Maximum Current Temperature Derating (V = 12V, Transverse Airflow). Extra ground pads installed. in 31.00 30.00 29.00 28.00 27.00 26.00 25.00 24.00 23.00 Natural Convection 22.00 100 LFM 21.00 200 LFM 20.00 19.00 18.00 17.00 16. ...
Page 12
... China: © 2008 Murata Power Solutions, Inc. Singapore: www.murata-ps.com LSM2-T/30-D12 Series DOSA-SMT, 30A POL DC/DC Converters Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0 01, email: france@murata-ps.com Mü ...