MDC_UEI-50-60W MURATA [Murata Manufacturing Co., Ltd.], MDC_UEI-50-60W Datasheet
MDC_UEI-50-60W
Related parts for MDC_UEI-50-60W
MDC_UEI-50-60W Summary of contents
Page 1
... This option offers additional cooling in low-airfl ow, high temperature applica- tions. GATE DRIVE BARRIER OPTO Reference, trim & Error Amplifier Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page OUT –V OUT +SENSE TRIM –SENSE +1 508 339 3000 ...
Page 2
... OUT OUT and higher OUT and OUT Note: Not all model number combinations are available. Contact Murata Power Solutions. Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page UEI Series Package Case (inches) Pinout 1.50x1.90x0.38 P52 1.50x1.90x0.38 P52 1.50x1.90x0.38 P52 1 ...
Page 3
... PINS 1.02±0.05 .02 STANDOFFS 0.5 BOTTOM VIEW C L .900 22.86 .200 5.08 5 .400 6 10. .400 7 10. .200 5. 1.800 45.72 UEI50 'Z' Series 50-60W (plastic case–preliminary) Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page .600 15.24 +1 508 339 3000 ...
Page 4
... As a practical matter in your application often diffi cult to determine how long an input overvoltage was applied. Therefore, do not exceed the continuous voltage rating. Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page Negative Logic OFF=open pin or +10 to +15V max. ON=Gnd pin or – ...
Page 5
... Range ºC ºC –40 to +85ºC; with Derating –55 to 125ºC 115 (see Notes) Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_UEI Series 50-60W.B24 Page Switching Frequency KHz 275 280 275 250 265 TBD Relative Humidity, ...
Page 6
... CURRENT PROBE 1 +INPUT L BUS C C BUS IN 2 −INPUT = 33μF, ESR < 700mΩ @ 100kHz = 220μF, ESR < 100mΩ @ 100kHz = 12μH Figure 2. Measuring Input Ripple Current Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page regulated OUT +1 508 339 3000 ...
Page 7
... DC/DC converter will enter a current-limiting mode. The output voltage will decrease proportionally with increases in output www.murata-ps.com UEI Series 50-60W Isolated Wide-Range DC/DC Converters Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page 508 339 3000 ...
Page 8
... Figure 5 – Trim adjustments using a trimpot 6 +OUTPUT 2 INPUT − 5 +SENSE 9 4 ON/OFF TRIM CONTROL R TRIM DOWN 8 SENSE − +INPUT OUTPUT − Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page 5-22 7 LOAD TURNS LOAD +1 508 339 3000 ...
Page 9
... The device is off (disabled) when the On/Off is left open Max. with respect to – Vcc 3 ON/OFF CONTROL 1 -INPUT Figure 8 – Driving the On/Off Control Pin (suggested circuit) Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page 508 339 3000 ...
Page 10
... LFM 24V, airflow is from pin 2 to pin 1) IN Natural Convection Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page 400 LFM 508 339 3000 ...
Page 11
... IN Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page 508 339 3000 ...
Page 12
... Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: MDC_UEI Series 50-60W.B24 Page 508 339 3000 ...