hd66789 Renesas Electronics Corporation., hd66789 Datasheet - Page 96

no-image

hd66789

Manufacturer Part Number
hd66789
Description
528-channel, One-chip Driver For Amorphous Tft Panels With 262,144-color Display Ram, Power Supply Circuit, And Gate Circuit
Manufacturer
Renesas Electronics Corporation.
Datasheet
HD66789
Rev.0.12, May 09 2003, page 96 of 156
Transition between the Internal Clock Operation Mode and RGB Interface Mode
Internal Clock Operation to RGB I/F (1)
Note: When switching into the RGB interface mode, the RGB
Wait more than 1 frame
RGB interface operation
Internal clock operation
RAM data write sequence through system interface in RGB-I/F mode
(DM1-0=01, RM=1)
interface signals, VSYNC, HSYNC, DOTCLK, and ENABLE,
must be input before the setting of DM1-0 and RM bits.
Writing RAM Data
HWM = 1, AM = 0
Address Setting
RGB I/F Setting
From RGB I/F (1) to RGB I/F (2)
setting (R22h)
Index resister setting (R22h)
Index resister
RGB I/F
RGB I/F mode setting
(DM1-0=01, RM=0)
Writing RAM Data
RGB I/F Operation
Address Setting
System I/F
HWM=1/0
Display operation
in synchronization with
the internal clock
The value set in DM1-0 and RM
become valid after the completion
of 1-frame display.
Display operation in
synchronization
with the RGB signal
RGB I/F (1) to Internal Clock Operation
Note: When switching into the internal clock mode from RGB I/F,
Internal clock mode setting
Wait more than 1 frame
Internal clock operation
(DM1-0 = 00, RM=0)
input for more than 1 frame after the mode has been switched.
keep RGB I/F signals (VSYNC, HSYNC, DOTCLK, ENABLE)
RGB I/F operation
From RGB I/F (2) to RGB I/F (1)
Index resister setting (R22h)
(DM1-0=01, RM=1)
Writing RAM Data
Address Setting
HWM=1, AM=0
RGB I/F mode
RGB I/F Operation
System I/F
Display operation in
synchronization with the RGB
signals ( VSYNC , HSYNC,
DOTCLK)
The value set in DM1-0 and RM bits
become valid after the completion of
1-frame display.
Display operation
in synchronization with
the internal clock
Preliminary