SS8017TR SSC [Silicon Standard Corp.], SS8017TR Datasheet

no-image

SS8017TR

Manufacturer Part Number
SS8017TR
Description
Two Remote Temperature Sensors with SMBus Serial Interface and System Reset
Manufacturer
SSC [Silicon Standard Corp.]
Datasheet
Rev.2.01 6/06/2003
Ordering Information
Applications
Features
Two channels: measures both remote and local
No calibration required
SMBus 2-wire serial interface
Programmable under/over-temperature alarms
SMBus alert response supported
Accuracy:
Average supply current during conversion of
Supply range of +3V to +5.5V
Small 8-lead SO package
Desktop and Notebook
Computers
Smart Battery Packs
LAN Servers
Industrial Controllers
temperatures
320µA (typ)
Example: SS8017TR
±1°C (+60°C to +100°C, remote)
±3°C (+60°C to + 100°C, local)
SS8017XX
à SS8017 shipped in tape and reel
Packing type
Central Office
Telecom Equipment
Test and Measurement
Multi-Chip Modules
TR: Tape and reel
www.SiliconStandard.com
Two Remote Temperature Sensors with
SMBus Serial Interface and System Reset
Description
The SS8017 contains a precise digital thermometer, a
system-reset circuit, and a programmable thermal
shutdown signal.
The thermometer reports the temperature of two re-
mote
ode-connected transistors , typically a low-cost, eas ily
mounted 2N3904 NPN type which replaces conve n-
tional thermistors or thermocouples. Remote accuracy
is ±5°C for multiple transistor manufacturers, with no
calibration needed. The remote channel can also
measure the die temperature of other ICs, such as mi-
croprocessors,
ode-connected transistor.
The 2-wire serial interface accepts standard System
Management Bus (SMBus
Send Byte, and Receive Byte commands to program
the alarm thresholds and to read temperature data. The
data format is 7 bits plus sign, with each bit corre-
sponding to 1 °C, in two’s-complement format. Meas-
urements can be done automatically and autono-
mously, with the conve rsion rate programmed by the
user or programmed to operate in a single-shot mode.
The adjustable rate a llows the user to control the
supply-current drain.
sensors.
that
The
contain
remote
TM
) Write Byte, Read Byte,
an
sensors
on-chip,
SS8017
are
1 of 16
di-
di-

Related parts for SS8017TR

SS8017TR Summary of contents

Page 1

... LAN Servers Multi-Chip Modules Industrial Controllers Ordering Information SS8017XX Packing type TR: Tape and reel Example: SS8017TR à SS8017 shipped in tape and reel Rev.2.01 6/06/2003 Two Remote Temperature Sensors with SMBus Serial Interface and System Reset Description The SS8017 contains a precise digital thermometer, a system-reset circuit, and a programmable thermal shutdown signal ...

Page 2

The SS8017 also contains a microprocessor ( µP)su- pervisory circuit used to monitor the power supplies in µP and digital systems. This provides excellent circuit reliability and low cost by eliminating external compo- nents and adjustments when used with 5V-powered ...

Page 3

Absolute Maximum Ratings VCC to GND………….….………………………………………………..……….-0.3V to +6V DXP to GND……….……………………………………………………..……..…-0.3V to VCC + 0.3V DXN to GND………………………………………………….……..……………..-0.3V to +0.8V SMBCLK, SMBDATA, ALERT to GND……………………………………...…-0.3V to +6V SMBDATA, ALERT Current………………………………………………..…….-1mA to +50mA DXN Current………………………………………………..…..………………….±1mA ESD Protection (SMBCLK, SMBDATA, ALERT , ...

Page 4

Electrical Characteristics (cont.) (VCC = + 3.3V 0°C to +85°C, unless otherwise noted.) A PARAMETER SMBus Interface Logic Input High Voltage Logic Input Low Voltage Logic Output Low Sink Current Output High Leakage Current Logic Input Current SMBus ...

Page 5

Pin Description PIN NAME 1,6,10,13,15 NC Not connected. 2 Vcc Supply Voltage Input, 4.5V to 5.5V. Bypass to GND with a 0.1µF capacitor. Combined Current Source and A/D Positive Input for remote-diode channel 1. Do not leave DXP1 floating; 3 ...

Page 6

Block Diagram DXP1 DXP1 DXP2 DXN DXN INTERNAL GROUND INTERNAL GROUND Detailed Description The SS8017 consists of two temperature sensors, one on-chip temperature sensor and includes a system-reset function. The temperature sensor is designed ...

Page 7

A/D Conversion Sequence If a Start command is written (or generated automati- cally in the free-running auto-convert mode), both two channels are converted, and the results of both meas- urements are available after the end of conversion. A BUSY status ...

Page 8

In this way, most parasitic thermocouple errors are swamped out. Use wide traces. Narrow ones are more inductive and tend to pick up radiated noise. The 10 mil widths and spacing recommended on Figure 2 aren't absolutely necessary (as they ...

Page 9

Ensuring a Valid Reset Output Down to V When V falls below 1V, the SS8017 RESET out- CC put no longer sinks current-it becomes an open cir- cuit. Therefore, high-impedance CMOS logic inputs connected to RESET can drift to undetermined ...

Page 10

Write Byte Format S Address WR 7 bits Slave Address: equivalent to chip-select line of a 3-wire interface Command Byte: selects, which register you, are writing to Data Byte: data goes into the register set by the command byte (to ...

Page 11

Table 3. Data Format (Twos-Complement) ROUND DIGITAL OUTPUT TEMP. TEMP. DATA BITS ( SIGN +130.00 +127 0 +127.00 +127 0 +126.50 +127 0 +126.00 +126 0 +25.25 +25 0 +0. +0. +0.00 +0 ...

Page 12

Table 4. Command-Byte Bit Assignments REGISTER COMMAND RRTE2 00h RRTE1 01h RSL 02h RCL 03h RCRA 04h RRHI2 05h RRLS2 06h RRHI1 07h RRLS1 08h WCA 09h WCRW 0Ah WRHA2 0Bh WRLN2 0Ch WRHA1 0Dh WRLN1 0Eh OSHT 0Fh TCRIT1 ...

Page 13

Table 5. Configuration-Byte Bit Assignments BIT NAME POR STATE 7 (MSB) MASK 0 6 RUN / STOP 0 5 DET_FAN 0 4 EN_TH_SHUT 1 3-0 FQ_TH_SHUT 0010b Table 6. Number of Faults assigned by FQ_TH_SHUT FQ_TH_SHUT Number of Faults 0000b ...

Page 14

Table 9. RLTS and RRTE Temp Register Update Timing Chart OPERATING CONVERSION MODE INITIATED BY: Auto-Convert Power-on reset 1-shot command, while idling be- Auto-Convert tween automatic conversions 1-shot command that occurs dur- Auto-Convert ing a conversion Auto-Convert Rate timer Auto-Convert ...

Page 15

V levels below 3V are not CC recommended. A second Vcc comparator, the ADC UVLO comparator, prevents the ADC from converting until there is sufficient headroom (Vcc = 2.8V typical). Power-Up Defaults: n Interrupt latch ...

Page 16

Physical Dimensions D ¢ X (4X Note: 1. Package body sizes exclude mold flash and gate burrs 2. Dimension L is measured in gage plane 3. Tolerance 0.10mm unless other wise specified 4. Controlling dimension is millimeter ...

Related keywords