x24042 ETC-unknow, x24042 Datasheet - Page 9

no-image

x24042

Manufacturer Part Number
x24042
Description
Serial E2prom
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
X24042
Quantity:
5 510
Part Number:
x24042P
Manufacturer:
XICOR
Quantity:
5 510
Part Number:
x24042P
Manufacturer:
AD
Quantity:
5 510
Part Number:
x24042P
Manufacturer:
XICOR
Quantity:
20 000
X24042
CAPACITANCE T
Notes: (1) Must perform a stop command prior to measurement.
ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias ................. –65 C to +135 C
Storage Temperature ...................... –65 C to +150 C
Voltage on any Pin with
D.C. Output Current ........................................... 5 mA
Lead Temperature
RECOMMENDED OPERATING CONDITIONS
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified)
Symbol
l
l
I
I
I
I
V
V
V
CC1
CC2
SB1 (1)
SB2 (1)
LI
LO
Respect to V
(Soldering, 10 Seconds) .............................. 300 C
lL (2)
IH
OL
Temperature
Commercial
Industrial
Military
(2)
Symbol
C
C
(2) V
(3) This parameter is periodically sampled and not 100%
I/O (3)
IN
(3)
not 100% tested.
tested.
V
V
V
V
Input Leakage Current
Output Leakage Current
Input Low Voltage
Input High Voltage
Output Low Voltage
IL
CC
CC
CC
CC
min and V
Supply Current (Read)
Supply Current (Write)
Standby Current
Standby Current
SS
Parameter
A
................................. –1.0V to +7V
= 25 C, F = 1.0MHZ, V
IH
Input/Output Capacitance (SDA)
Input Capacitance (A
max. are for reference only and are
–40 C
–55 C
Min.
0 C
Test
V
CC
+125 C
Min.
–1.0
+85 C
Max.
70 C
0
CC
x 0.7 V
, A
3849 PGM T02
Limits
= 5V
1
, A
V
2
, SCL)
CC
CC
Max.
150
0.4
50
10
10
1
3
x 0.3
+ 0.5
9
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
Units
mA
Supply Voltage
V
V
V
Max.
A
A
A
A
X24042
X24042-3
X24042-2.7
8
6
SCL = V
@ 100 KHz, SDA = Open, All Other
Inputs = GND or V
SCL = SDA = V
Inputs = GND or V
SCL = SDA = V
Inputs = GND or V
V
V
I
OL
IN
OUT
= 3 mA
= GND to V
= GND to V
Units
pF
pF
CC
Test Conditions
x 0.1/V
CC
CC
CC
CC
CC
CC
CC
– 0.3V, All Other
– 0.3V, All Other
CC
, V
, V
x 0.9 Levels
– 0.3V
4.5V to 5.5V
3.0V to 5.5V
2.7V to 5.5V
Conditions
CC
CC
V
V
Limits
I/O
IN
= 5.5V
= 3V
= 0V
= 0V
3849 PGM T03
3849 PGM T05
3849 PGM T04

Related parts for x24042