RR2 SYSTEMSENSOR [Systemsensor advanced ideas.], RR2 Datasheet - Page 2

no-image

RR2

Manufacturer Part Number
RR2
Description
Polarity Reversal Relay Module
Manufacturer
SYSTEMSENSOR [Systemsensor advanced ideas.]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RR2012(0805)L101JT 100R 5%
Manufacturer:
SUPEROHM
Quantity:
20 000
Part Number:
RR255LA-400 TR
Quantity:
2 028
Company:
Part Number:
RR255LA-400 TR
Quantity:
2 844
Part Number:
RR255LA-400TR
Manufacturer:
TI
Quantity:
3 883
Part Number:
RR255M-400
Manufacturer:
ROHM
Quantity:
99 000
Part Number:
RR255M-400TR
Manufacturer:
FREESCALE
Quantity:
592
Part Number:
RR255M-400TR
Manufacturer:
ROHM
Quantity:
99 000
Part Number:
RR263M-400TR
Manufacturer:
ROHM
Quantity:
4 000
Part Number:
RR264M-40
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
RR264M-400
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Frequently Asked Questions
Q. What advantage does the RR2 have over the RR1?
A. The RR2 has the ability to differentiate between
Q. What panel types are compatible with the RR2?
A. The RR2 can be used with 2-wire, 4-wire, 12 VDC or
Q. Does the RR2 operate with Ademco panels? Are
A. The RR2 operates with Ademco panels and does not
Q. Does the RR2 operate with continuous and coded
A. The RR2 offers a field-selectable switch for setting the
2-Wire System Triggered from IAC/Bell Circuit:
UL LISTED
2-Wire System Triggered from Alarm Relay Contact:
System Sensor Headquarters
3825 Ohio Avenue
St. Charles, IL 60174
Ph: 800/736-7672
Fx: 630/377-6495
Documents-on-Demand:
800/736-7672 x3
Web: www.systemsensor.com
©2001 System Sensor. The company reserves the right to change product specifications without notice.
CONTROL
UL LISTED
CONTROL
System Sensor Sales and Service
ALARM
ALARM
PANEL
PANEL
continuous and pulsed panel outputs and can be
used on single output panels.
24 VDC single or combination output panels.
separate Ademco modules also required?
require a separate Ademco module.
(pulsed) alarm signals?
RR2 for continuous or coded outputs.
(NO Contact)
AUX POWER
AUX POWER
(positive signal
in alarm state)
INITIATING
ALARM
RELAY
INITIATING
CIRCUIT
ALARM
BELL/
CIRCUIT
CIRCUIT
+
+
+
+
ORANGE
YELLOW
ORANGE
YELLOW
IN+
IN–
PWR+
BLACK
PWR–
IN–
IN+
PURPLE
RED
PWR+
BLACK
PWR–
RED
PURPLE
T+
T+
System Sensor in Canada
Ph: 905/812-0767
Fx: 905/812-0771
System Sensor in Europe
Ph: + 44.1403.276500
Fx: + 44.1403.276501
BROWN
BROWN
OUT+
OUT+
WHITE
WHITE
OUT–
OUT–
RA400Z
RA400Z
+
+
System Sensor in China
Ph: + 86.29.524.6253
Fx: + 86.29.524.6259
System Sensor in Singapore
Ph: + 65.273.2230
Fx: + 65.273.2610
A
A
A
A
+
+
+
+
+
-
+
-
Not
Used
Not
Used
Power
Power
RA400Z
RA400Z
+
+
Q. Are there any special wiring instructions to follow with
A. Polarity should be observed and the RR2 must be
Q. What kind of panel outputs are required for use with
A. The RR2 can be used with fire control panels with a
Q. Does the RR2 accommodate more than one 2-wire
A. Yes, more than one model 2100AT can be placed on a
* Current supply must be adequate per appropriate calculations.
the RR2?
connected to an auxiliary power supply.
the RR2?
bell/alarm output or an alarm relay output.
sounder detector (2100AT) on a loop?
zone when the panel switches to a reverse polarity, non-
current-limited auxiliary power supply*. Refer to
wiring diagrams below for specific 2-wire detector
wiring.
A
A
A
A
+
+
+
+
System Sensor in the Far East
Ph: + 852.21919003
Fx: + 852.27366580
System Sensor in Australia
Ph: + 613.54.281.142
Fx: + 613.54.281.172
+
-
+
-
Not
Used
Not
Used
Power
Power
EOL
EOL
NOTE:
If optional Style A (Class A)
wiring is used, a second RR2
module must be added to
enable concurrent loop
polarity reversal.
System Sensor in India
Ph: + 91.11.558.2119
Fx: + 91.11.527.6815
A05-0313-000•3/01(5K)•#733

Related parts for RR2