RR2 SYSTEMSENSOR [Systemsensor advanced ideas.], RR2 Datasheet

no-image

RR2

Manufacturer Part Number
RR2
Description
Polarity Reversal Relay Module
Manufacturer
SYSTEMSENSOR [Systemsensor advanced ideas.]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RR2012(0805)L101JT 100R 5%
Manufacturer:
SUPEROHM
Quantity:
20 000
Part Number:
RR255LA-400 TR
Quantity:
2 028
Company:
Part Number:
RR255LA-400 TR
Quantity:
2 844
Part Number:
RR255LA-400TR
Manufacturer:
TI
Quantity:
3 883
Part Number:
RR255M-400
Manufacturer:
ROHM
Quantity:
99 000
Part Number:
RR255M-400TR
Manufacturer:
FREESCALE
Quantity:
592
Part Number:
RR255M-400TR
Manufacturer:
ROHM
Quantity:
99 000
Part Number:
RR263M-400TR
Manufacturer:
ROHM
Quantity:
4 000
Part Number:
RR264M-40
Manufacturer:
VISHAY/威世
Quantity:
20 000
Part Number:
RR264M-400
Manufacturer:
ROHM/罗姆
Quantity:
20 000
RR2
Polarity Reversal
Relay Module
Model
RR2
General Description
The RR2 Polarity Reversal Relay
Module is intended for use with
2-wire and 4-wire detectors with
built-in sounder, such as the following
System Sensor models: 2100AT,
2112/24AT, 2112/24ATR and
2112/24AITR. Per NFPA require-
ments, the RR2 is designed to allow
all detectors on a loop to sound when
one goes into alarm. The RR2 can dif-
ferentiate between steady and pulsed
panel outputs.
Product Overview
Can be used with a single alarm
output panel that provides both
coded (pulsed) output for fire and
continuous output for burglary.
Fulfills NFPA 72 requirement for
sounder models
Designed for use with System
Sensor 2100 Series sounder
models
Colored wires facilitate easy
installation
Compatible with 2-wire and
4-wire smoke detectors
Can be used with 12 VDC and
24 VDC systems
Plug-in quick disconnects for
easy wiring
Specifications
Operating Voltage Range:
Maximum Operating Current
Relay Contacts:
Operating Temperature Range:
Operating Humidity Range:
Dimensions:
Wire connections:
RR2
8.5 to 35 VDC
25mA
2A at 35 VDC
32° to 131° F (0° to 55° C)
5% to 95% non-condensing
2
18 AWG stranded, tinned, 16" long
1
/
2
" x 2
1
/
2
" x 1"

Related parts for RR2

RR2 Summary of contents

Page 1

... System Sensor models: 2100AT, 2112/24AT, 2112/24ATR and 2112/24AITR. Per NFPA require- ments, the RR2 is designed to allow all detectors on a loop to sound when one goes into alarm. The RR2 can dif- ferentiate between steady and pulsed panel outputs. Product Overview Can be used with a single alarm output panel that provides both coded (pulsed) output for fi ...

Page 2

... Q. What panel types are compatible with the RR2? A. The RR2 can be used with 2-wire, 4-wire, 12 VDC or 24 VDC single or combination output panels. Q. Does the RR2 operate with Ademco panels? Are separate Ademco modules also required? A ...

Related keywords