esda6v2s6 STMicroelectronics, esda6v2s6 Datasheet - Page 3

no-image

esda6v2s6

Manufacturer Part Number
esda6v2s6
Description
Transil Array For Esd Protection
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ESDA6V2S6
Quantity:
3 521
Part Number:
esda6v2s6RL
Manufacturer:
ST
0
CALCULATION OF THE CLAMPING VOLTAGE
USE OF THE DYNAMIC RESISTANCE
The ESDA family has been designed to clamp fast
spikes like ESD. Generally the PCB designers
need to calculate easily the clamping voltage V
This is why we give the dynamic resistance in
addition to the classical parameters. The voltage
across the protection cell can be calculated with
the following formula:
WhereIpp is the peakcurrent throughthe ESDAcell.
DYNAMIC RESISTANCE MEASUREMENT
a more adapted test wave, as below defined, to the
classical 8/20 s and 10/1000 s surges.
I
Ipp
The short duration of the ESD has led us to prefer
2.5 s duration measurement wave.
V
CL
tp = 2.5 s
2 s
= V
BR
+ Rd I
PP
CL
t
.
As the value of the dynamic resistance remains
stable for a surge duration lower than 20 s, the
2.5 s rectangular surge is well adapted. In addition
both rise and fall times are optimized to avoid any
parasitic phenomenon during the measurement of
Rd.
ESDA6V1S3 / ESDA6V2S6
3/7

Related parts for esda6v2s6