Summary
The PSA series of positive switching regulators is de-
signed as power supply modules for electronic systems.
Their major advantages include a high level of efficiency
that remains virtually constant over the entire input range,
high reliability, low ripple and excellent dynamic response.
Type Survey and Key Data
Table 1: Type survey
1
2
Table of Contents
Summary ......................................................................... 1
Type Survey and Key Data .............................................. 1
Type Key .......................................................................... 2
Functional Description ..................................................... 2
Electrical Input Data ........................................................ 3
Electrical Output Data ..................................................... 4
Electromagnetic Compatibility (EMC) ............................. 6
REV. SEP 17, 2003
See also: Electrical Input Data: DU
Efficiency at U
• High efficiency up to 93%
• Wide input voltage range
• Low input to output differential voltage
• Very good dynamic properties
• Input undervoltage lock-out
• Parallel configurations possible
• Continuous no-load and short-circuit proof
• No derating
Safety according to IEC/EN 60950
Input voltage up to 60 V DC
Single output of 3.3...24 V DC
No input to output isolation
U
voltage
Output
o nom
5.1
5.1
12
15
24
[V]
i nom
and I
I
current
Output
o nom
o nom
2.5
2
5
3
3
[A]
.
io min
voltage range
.
U
15...40
19...40
29...60
Input
8...40
7...35
i
[V]
1
Page
Page 1 of 11
U
voltage
Input
i nom
20
20
20
30
40
Positive Switching Regulator
[V]
Modules with input voltages up to 60 V are specially de-
signed for secondary switched and battery driven applica-
tions. The case design allows operation at nominal load up
to 50°C without additional cooling.
Immunity to Environmental Conditions ........................... 6
Mechanical Data .............................................................. 7
Safety and Installation Instructions ................................. 7
Description of Options ..................................................... 9
Accessories ................................................................... 10
EC Declaration of Conformity ....................................... 11
PSA Series Extended Data Sheet
Efficiency
min
75
83
89
90
93
[%]
2
PSA 5A2-2
PSA 5A5-2
PSA 123-2
PSA 153-2
PSA 242.5-2
designation
Type
s (Benign)
50
2.0"
package
Options
iRY
70
2.8"
Page
25
1.0"

Related parts for psa242.5-2iry

psa242.5-2iry Summary of contents

Page 1

Input voltage Single output of 3.3... input to output isolation • High efficiency up to 93% • Wide input voltage range • Low input to output differential voltage • Very good dynamic ...

Page 2

Type Key Positive switching regulator in case A01 .................... PSA Nominal output voltage in volt (5 A for 5.1 V) ......... 5A...24 Nominal output current in ampere .............................. 2...5 Operational ambient temperature range T –10...50°C ........................................................... -2 Options package: Inhibit ...

Page 3

Electrical Input Data General Conditions 25°C, unless T A Table 2a: Input data Input Characteristics U Operating input voltage i DU Min. diff. voltage U – min Undervoltage lock-out ...

Page 4

Electrical Output Data General Conditions: – 25°C, unless T is specified A C – With R option, output voltage U o Table 3a: Output data Output Characteristics U Output voltage Output current o I Output ...

Page 5

... The output protection is not designed to withstand externally applied overvoltages. The user should ensure that systems with Power-One power supplies, in the event of a failure, do not result in an unsafe condition (fail-safe). REV. SEP 17, 2003 ...

Page 6

Electromagnetic Compatibility (EMC) Electromagnetic Immunity General condition: Case not earthed. Table 4: Immunity type tests 1 Phenomenon Standard Class Level Electrostatic IEC/EN 2 discharge 61000-4-2 Electromagnetic IEC/EN 2 field 61000-4-3 Electrical fast IEC/EN 2 transient/burst 61000-4-4 3 Surge IEC/EN 1 ...

Page 7

Table 7: MTBF MTBF MTBF acc. to MIL-HDBK-217F Mechanical Data Dimensions in mm. Tolerances ±0.3 mm unless otherwise specified. 20.5 18.7 6.3 1.2 Go– Vo+ i Gi– Vi+ ±0.2 2.7 ±0.2 50.2 min. 5 2.8 x 0.5 (1.0 x 0.5 ...

Page 8

... V DC This test is performed as factory test in accordance with IEC/EN 60950 and UL 1950 and should not be repeated in the field. Power-One will not honour any guarantee claims resulting from electric strength field tests. Safety of Operator Accessible Output Circuit ...

Page 9

Description of Options With this series, the options i (inhibit), R (control input for output voltage adjustment) and Y (small soldering pins) are defined as a package. Other combinations or parts of this package are not available. i Inhibit for ...

Page 10

... For detailed information see: Accessories on the Power- One homepage. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. ...

Page 11

... EMC directive can be presumed. Uster, 1 Sep. 2003 REV. SEP 17, 2003 Positive Switching Regulator EC Declaration of Conformity We Power-One AG Power-One AG Rolf Baldauf Director Engineering Page PSA Series Extended Datasheet s (Benign) Johann Milavec Director Products and IP ...