psa242.5-2iry Power-One, psa242.5-2iry Datasheet
psa242.5-2iry
Related parts for psa242.5-2iry
psa242.5-2iry Summary of contents
Page 1
Input voltage Single output of 3.3... input to output isolation • High efficiency up to 93% • Wide input voltage range • Low input to output differential voltage • Very good dynamic ...
Page 2
Type Key Positive switching regulator in case A01 .................... PSA Nominal output voltage in volt (5 A for 5.1 V) ......... 5A...24 Nominal output current in ampere .............................. 2...5 Operational ambient temperature range T –10...50°C ........................................................... -2 Options package: Inhibit ...
Page 3
Electrical Input Data General Conditions 25°C, unless T A Table 2a: Input data Input Characteristics U Operating input voltage i DU Min. diff. voltage U – min Undervoltage lock-out ...
Page 4
Electrical Output Data General Conditions: – 25°C, unless T is specified A C – With R option, output voltage U o Table 3a: Output data Output Characteristics U Output voltage Output current o I Output ...
Page 5
... The output protection is not designed to withstand externally applied overvoltages. The user should ensure that systems with Power-One power supplies, in the event of a failure, do not result in an unsafe condition (fail-safe). REV. SEP 17, 2003 ...
Page 6
Electromagnetic Compatibility (EMC) Electromagnetic Immunity General condition: Case not earthed. Table 4: Immunity type tests 1 Phenomenon Standard Class Level Electrostatic IEC/EN 2 discharge 61000-4-2 Electromagnetic IEC/EN 2 field 61000-4-3 Electrical fast IEC/EN 2 transient/burst 61000-4-4 3 Surge IEC/EN 1 ...
Page 7
Table 7: MTBF MTBF MTBF acc. to MIL-HDBK-217F Mechanical Data Dimensions in mm. Tolerances ±0.3 mm unless otherwise specified. 20.5 18.7 6.3 1.2 Go– Vo+ i Gi– Vi+ ±0.2 2.7 ±0.2 50.2 min. 5 2.8 x 0.5 (1.0 x 0.5 ...
Page 8
... V DC This test is performed as factory test in accordance with IEC/EN 60950 and UL 1950 and should not be repeated in the field. Power-One will not honour any guarantee claims resulting from electric strength field tests. Safety of Operator Accessible Output Circuit ...
Page 9
Description of Options With this series, the options i (inhibit), R (control input for output voltage adjustment) and Y (small soldering pins) are defined as a package. Other combinations or parts of this package are not available. i Inhibit for ...
Page 10
... For detailed information see: Accessories on the Power- One homepage. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. ...
Page 11
... EMC directive can be presumed. Uster, 1 Sep. 2003 REV. SEP 17, 2003 Positive Switching Regulator EC Declaration of Conformity We Power-One AG Power-One AG Rolf Baldauf Director Engineering Page PSA Series Extended Datasheet s (Benign) Johann Milavec Director Products and IP ...