ps-4sr Omron Corporation, ps-4sr Datasheet - Page 3

no-image

ps-4sr

Manufacturer Part Number
ps-4sr
Description
Electrode Holder
Manufacturer
Omron Corporation
Datasheet
Mounting
■ PS-3S Electrode Holders
Note: 1. OMRON does not sell couplings.
1. Mounting Electrode Holder
• Screw the Electrode Holder into the coupling
secured at the installation location.
Twin
clockwise
2. Screw in the Electrode until it reaches the bottom of the nut. Insufficient insertion will cause a faulty connection.
Coupling
Electrode
Holder
2. Attaching Electrode(s) to Electrode section
• Insert each Electrode into the connecting nut,
• Connect the leads, inserted through the hole
secure the Electrode with the clamp screws,
and then tighten the lock nut.
of the rubber bushing, into the respective ter-
minals.
Electrode section
housing
Lock nut
Rubber
bushing
Electrode
3. Inserting Electrode section into Electrode
Holder
• Fit the Electrode section into the Electrode
• Check the Electrode section for proper wir-
Holder and secure it with the two screws.
ing, fit the rubber bushing in position, and
then cover the Electrode Holder with the drip-
proof cover.
Electrode
Holder
Electrode
section
housing
Drip-proof
cover
PS-@S(R)/-31