lb1863m Sanyo Semiconductor Corporation, lb1863m Datasheet - Page 5

no-image

lb1863m

Manufacturer Part Number
lb1863m
Description
Two-phase Unipolar Brushless Motor Driver Automatic Recovery Type Circuit In A Miniature Flat Package
Manufacturer
Sanyo Semiconductor Corporation
Datasheet
4. Output protection function (C pin)
5. Rotation detection signal (RD pin)
6. Radio-frequency noise reduction function (B1 and B2 pins)
7. Thermal shutdown function
This pin connects the capacitor that forms the automatic recovery circuit. If rotation stops due to, for example, a
motor overload, the pin voltage rises and the output stops. The system automatically recovers from stopped to drive
mode when the load is set to an appropriate level. The lock detection time can be set by changing the value of the
capacitor.
This is an open collector output, and outputs a low level in drive mode and a high level when the motor is stopped.
These are base pins for Darlington pair outputs. Add capacitors of about 0.01 to 0.1 µF if radio-frequency noise is a
problem.
Turns off the output in response to coil shorting or IC overheating.
While the blades are turning, the capacitor is charged with a current of about 3 µA (typical), and C is discharged by
pulses that correspond to the motor speed.
When the blades lock, the capacitor is no longer discharged, and the voltage across the capacitor increases. The
output is turned off when that voltage reaches 0.8 V
When the output is turned off, the capacitor is discharged at a current of about 0.44 µA (typical). When the
capacitor voltage falls under V
V
ton:toff ratio of about 1:6 to protect the motor.
If the lock state has been cleared when the capacitor voltage reaches V
output on.
TH
For a 1-µF capacitor:Lock detection time
1. (Note that the output is turned on at this time.) These operations, i.e. items
Lock protection time (output on) About 1 second
TH
2, if the lock state is not yet cleared the capacitor continues discharging until
Automatic recovery circuit pin C voltage
LB1863M/LB1869M
(output off) About 6 seconds
IN
.
About 2 seconds
TH
2, motor rotation is started by turning the
and
, are repeated with a
No. 4943-5/6

Related parts for lb1863m