hsp50016 Intersil Corporation, hsp50016 Datasheet - Page 8

no-image

hsp50016

Manufacturer Part Number
hsp50016
Description
Digital Down Converter
Manufacturer
Intersil Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
hsp50016JC
Manufacturer:
TI
Quantity:
55
Part Number:
hsp50016JC-52
Manufacturer:
HARRIS
Quantity:
12 388
Part Number:
hsp50016JC-75
Manufacturer:
RENESAS
Quantity:
101
Part Number:
hsp50016JC-75
Manufacturer:
HARRIS
Quantity:
53
Part Number:
hsp50016JC-75
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
hsp50016JM-52
Manufacturer:
FSC
Quantity:
97
COMMAND
BYE, EXIT,
WCW
RCW
WCS
QUIT
RCS
RDO
ODF
TMS
TDO
ERR
RES
PDF
TCK
TRS
PPC
CLK
PTF
DIN
IQS
TDI
PP
?
ARGUMENT
CONTENTS
REGISTER
CONTROL
NUMBER
NUMBER
NUMBER
COUNT
WORD
WORD
INPUT
INPUT
INPUT
NAME
NAME
PORT
DATA
(1 - 3)
FILE
FILE
0/1
0/1
0/1
0/1
#1
3-8
TABLE 2. COMMAND LIST FOR COMMAND LINE INTERFACE SOFTWARE
ARGUMENT
ADDRESS
UPDATE
OUTPUT
OUTPUT
BOARD
NAME
NAME
(0 - 7)
FILE
FILE
BIT
#2
S
ARGUMENT
CONTROL
COUNT
WORD
#3
HSP50016-EV
Loads the specified control word of the HSP50016 with the 36-bit hexadeci-
mal value specified in Argument #3. Setting the update bit = 1 updates the
configuration of the DDC; update bit = 0 only modifies the control word.
Reads one of the HSP50016’s control words to the screen. If Argument #1 is
omitted, all control words are displayed.
Loads the evaluation board’s control register with a 16-bit hexadecimal value.
Displays the last value loaded into the evaluation board’s control register.
Does not read the current contents of the register.
Loads the HSP50016’s DATA0-15 input with the 16-bit value specified in Ar-
gument #1.
Toggles PCCLK, the software clock to the DDC, the specified number of
times. If Argument #1 is omitted, COUNT = 1.
Resets the DDC and cycles CLK five times.
Sets the state of the IQSTRT line.
Reads the output I and Q data of the DDC to the screen.
Process Data File: Read one sample from input file, write it to DATA0-15, re-
peat until output data becomes available, then read outputs, write to output
file. Repeat until all samples in the data input file have been read. Perform this
entire process for the number of times specified by Argument #3. If Argument
#3 is omitted, input file is read one time.
Output data file format: 0 = hexadecimal, 1 = floating point.
Toggle TCLK one cycle.
Write TRST low, then high.
Write one bit to TMS pin.
Write one bit to TDI pin.
Read one bit from TDO pin.
Process Test File: Write bit patterns specified in input file to TAP; read TAP
output and store in output file. See Appendix B for TAP file format.
Change the printer port and HSP50016-EV board address that the DDCCMD
program is using for communication between the PC and the evaluation board
to those specified in arguments 1 and 2. The board address is set by inserting
a jumper one of the headers JP6-13.
Display the printer port and HSP50016-EV board address that the DDCCMD
Program is using for communication to the PC.
Display the state of the error bit:
0 =...No error.
1 =...Software unable to execute command; e.g., a syntax error was detected
in the command line, an RDO command was executed while DDC was exe-
cuting a data output cycle, and so on. A correctly executed command clears
the bit, except for ERR, BYE, EXIT and QUIT, which have no effect on the er-
ror bit.
List available commands together with a brief description.
Any one of these terminates interactive mode.
COMMAND DESCRIPTION