xr16m2650im48 Exar Corporation, xr16m2650im48 Datasheet - Page 31

no-image

xr16m2650im48

Manufacturer Part Number
xr16m2650im48
Description
High Performance Low Voltage Duart With 32-byte Fifo
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
xr16m2650im48-F
Manufacturer:
Exar Corporation
Quantity:
10 000
REV. 1.0.2
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. The THR bit is set to HIGH when the last data byte is
transferred from the transmit holding register to the transmit shift register. The bit is reset to LOW concurrently
with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set when the
transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.
LSR[6]: THR and TSR Empty Flag
This bit is set to HIGH whenever the transmitter goes idle. It is set to LOW whenever either the THR or TSR
contains a data character. In the FIFO mode this bit is set to HIGH whenever the transmit FIFO and transmit
shift register are both empty.
LSR[7]: Receive FIFO Data Error Flag
This register provides the current state of the modem interface input signals. Lower four bits of this register are
used to indicate the changed information. These bits are set to HIGH whenever a signal from the modem
changes state. These bits may be used for general purpose inputs when they are not used with modem
signals.
MSR[0]: Delta CTS# Input Flag
MSR[1]: Delta DSR# Input Flag
MSR[2]: Delta RI# Input Flag
MSR[3]: Delta CD# Input Flag
MSR[4]: CTS Input Status
CTS# pin may function as automatic hardware flow control signal input if it is enabled and selected by Auto
CTS (EFR bit-7). Auto CTS flow control allows starting and stopping of local data transmissions based on the
modem CTS# signal. A HIGH on the CTS# pin will stop UART transmitter as soon as the current character has
finished transmission, and a LOW will resume data transmission. Normally MSR bit-4 bit is the complement of
the CTS# input. However in the loopback mode, this bit is equivalent to the RTS# bit in the MCR register. The
CTS# input may be used as a general purpose input when the modem interface is not used.
4.9
Logic 0 = No FIFO error (default).
Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error
or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the
RX FIFO.
Logic 0 = No change on CTS# input (default).
Logic 1 = The CTS# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
Logic 0 = No change on DSR# input (default).
Logic 1 = The DSR# input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
Logic 0 = No change on RI# input (default).
Logic 1 = The RI# input has changed from a LOW to HIGH, ending of the ringing signal. A modem status
interrupt will be generated if MSR interrupt is enabled (IER bit-3).
Logic 0 = No change on CD# input (default).
Logic 1 = Indicates that the CD# input has changed state since the last time it was monitored. A modem
status interrupt will be generated if MSR interrupt is enabled (IER bit-3).
Modem Status Register (MSR) - Read Only
HIGH PERFORMANCE LOW VOLTAGE DUART WITH 32-BYTE FIFO