xr16m2752 Exar Corporation, xr16m2752 Datasheet - Page 38

no-image

xr16m2752

Manufacturer Part Number
xr16m2752
Description
High Performance Duart With 64-byte Fifo
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
xr16m2752IJ44-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
xr16m2752IL32-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
XR16M2752
1.62V TO 3.63V HIGH PERFORMANCE DUART WITH 64-BYTE FIFO
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is
selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and
RTS de-asserts HIGH at the next upper trigger level or hysteresis level. RTS# will return LOW when FIFO data
falls below the next lower trigger level. The RTS# output must be asserted (LOW) before the auto RTS can
take effect. RTS# pin will function as a general purpose output when hardware flow control is disabled.
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, see
4.19.1
Logic 0 = Automatic RTS flow control is disabled (default).
Logic 1 = Enable Automatic RTS flow control.
Logic 0 = Automatic CTS flow control is disabled (default).
Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts HIGH.
Data transmission resumes when CTS# returns LOW.
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write
Table
6.
38
REV. 1.0.0