mc9s08jm60 Freescale Semiconductor, Inc, mc9s08jm60 Datasheet - Page 152

no-image

mc9s08jm60

Manufacturer Part Number
mc9s08jm60
Description
Hcs08 Microcontrollers
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc9s08jm60CGT
Manufacturer:
FREESCALE
Quantity:
5 200
Part Number:
mc9s08jm60CGT
Manufacturer:
FREESCALE
Quantity:
5 200
Part Number:
mc9s08jm60CLD
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s08jm60CLDR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s08jm60CLH
Manufacturer:
FREESCALE
Quantity:
2 500
Part Number:
mc9s08jm60CLH
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc9s08jm60CLHE
Manufacturer:
AZBIL
Quantity:
1 000
Analog-to-Digital Converter (S08ADC12V1)
When a conversion is aborted, the contents of the data registers, ADCRH and ADCRL, are not altered.
However, they continue to be the values transferred after the completion of the last successful conversion.
If the conversion was aborted by a reset, ADCRH and ADCRL return to their reset states.
10.4.4.4
The ADC module remains in its idle state until a conversion is initiated. If ADACK is selected as the
conversion clock source, the ADACK clock generator is also enabled.
Power consumption when active can be reduced by setting ADLPC. This results in a lower maximum
value for f
10.4.4.5
The total conversion time depends on the sample time (as determined by ADLSMP), the MCU bus
frequency, the conversion mode (8-bit, 10-bit or 12-bit), and the frequency of the conversion clock (
After the module becomes active, sampling of the input begins. ADLSMP selects between short (3.5
ADCK cycles) and long (23.5 ADCK cycles) sample times.When sampling is complete, the converter is
isolated from the input channel and a successive approximation algorithm is performed to determine the
digital value of the analog signal. The result of the conversion is transferred to ADCRH and ADCRL upon
completion of the conversion algorithm.
If the bus frequency is less than the f
cannot be guaranteed when short sample is enabled (ADLSMP=0). If the bus frequency is less than 1/11th
of the f
sample is enabled (ADLSMP=1).
152
The maximum total conversion time for different conditions is summarized in
Single or first continuous 10-bit or 12-bit
Single or first continuous 10-bit or 12-bit
Single or first continuous 10-bit or 12-bit
Single or first continuous 10-bit or 12-bit
Subsequent continuous 10-bit or 12-bit;
Subsequent continuous 10-bit or 12-bit;
ADCK
Single or first continuous 8-bit
Single or first continuous 8-bit
Single or first continuous 8-bit
Single or first continuous 8-bit
Subsequent continuous 8-bit;
Subsequent continuous 8-bit;
ADCK
frequency, precise sample time for continuous conversions cannot be guaranteed when long
Power Control
Sample Time and Total Conversion Time
Conversion Type
f
f
BUS
BUS
f
f
BUS
BUS
(see the electrical specifications).
> f
> f
> f
> f
ADCK
ADCK
ADCK
ADCK
Table 10-13. Total Conversion Time vs. Control Conditions
/11
/11
MC9S08JM60 Series Data Sheet, Rev. 2
ADCK
frequency, precise sample time for continuous conversions
ADICLK
0x, 10
0x, 10
0x, 10
0x, 10
11
11
11
11
xx
xx
xx
xx
ADLSMP
0
0
1
1
0
0
1
1
0
0
1
1
23 ADCK cycles + 5 bus clock cycles
43 ADCK cycles + 5 bus clock cycles
20 ADCK cycles + 5 bus clock cycles
40 ADCK cycles + 5 bus clock cycles
5 μs + 20 ADCK + 5 bus clock cycles
5 μs + 23 ADCK + 5 bus clock cycles
5 μs + 40 ADCK + 5 bus clock cycles
5 μs + 43 ADCK + 5 bus clock cycles
Max Total Conversion Time
17 ADCK cycles
20 ADCK cycles
37 ADCK cycles
40 ADCK cycles
Table