z8f1621 ZiLOG Semiconductor, z8f1621 Datasheet - Page 130

no-image

z8f1621

Manufacturer Part Number
z8f1621
Description
High Performance 8-bit Microcontrollers
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
z8f1621AN020EC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020EC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020EG
Manufacturer:
Zilog
Quantity:
356
Part Number:
z8f1621AN020EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020SC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020SC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z8f1621AN020SG
Manufacturer:
Zilog
Quantity:
918
Part Number:
z8f1621PM020SG
Manufacturer:
Zilog
Quantity:
673
Part Number:
z8f1621VN020SG
Manufacturer:
Zilog
Quantity:
6
Table 58. UART Address Compare Register (UxADDR)
PS019921-0308
BITS
FIELD
RESET
R/W
ADDR
UART Address Compare Register
UART Baud Rate High and Low Byte Registers
7
1 = Infrared Encoder/Decoder is enabled. The UART transmits and receives data
The UART Address Compare register
the UART. When the MPMD[1] bit of UART Control Register 0 is set, all incoming
address bytes are compared to the value stored in the Address Compare register. Receive
interrupts and RDA assertions only occur in the event of a match.
COMP_ADDR—Compare Address
This 8-bit value is compared to the incoming address bytes.
The UART Baud Rate High and Low Byte registers (see
page 117) combine to create a 16-bit baud rate divisor value (BRG[15:0]) that sets the data
transmission rate (baud rate) of the UART. To configure the Baud Rate Generator as a
timer with interrupt on time-out, complete the following procedure:
1. Disable the UART by clearing the REN and TEN bits in the UART Control 0 register
2. Load the desired 16-bit count value into the UART Baud Rate High and Low Byte
3. Enable the Baud Rate Generator timer function and associated interrupt by setting the
When configured as a general purpose timer, the UART BRG interrupt interval is calcu-
lated using the following equation:
to 0.
registers.
BRGCTL bit in the UART Control 1 register to 1.
through the Infrared Encoder/Decoder.
UART BRG Interrupt Interval s ( )
6
5
=
F45H and F4DH
System Clock Period (s) BRG 15:0
COMP_ADDR
4
(Table
R/W
0
58) stores the multi-node network address of
3
Z8 Encore! XP
×
Table 59
2
[
Product Specification
]
and
Table 60
1
®
F64XX Series
on
0
UART
116