at3210 Aimtron Technology, at3210 Datasheet - Page 12

no-image

at3210

Manufacturer Part Number
at3210
Description
16 Grayscales 160x160 Stn Lcd Controller
Manufacturer
Aimtron Technology
Datasheet
Command Descriptions
Double Byte Command (8080-series interface)
*First byte command is the index of command register. Second byte command is the
value of command register
Command
Display data write
Display data read
LUT
XWS
YWS
XWE
YWE
XP
YP
ADC
DISPREV
DISPOFF
SRESET
COMDIR
TEST
FIRSTL
CLINE0
CLINE1
CLINE2
BKCOLOR
AIMTRON TECHNOLOGY CORP.
2F,NO.10, Prosperity Rd. II, Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C
Email:
Tel: 886-3-563-0878
service@aimtron.com.tw
Command code (See
0
RS RD WR
1 1 0
1 0 1
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
0 1 0
1 0
D7 D6 D5 D4 D3 D2 D1 D0
d7 d6 d5 d4 d3 d2 d1 d0
d7 d6 d5 d4 d3 d2 d1 d0
d15 d14 d13 d12 d11 d10 d9 d8
d7 d6 d5 d4 d3 d2 d1 d0
d7 d6 d5 d4 d3 d2 d1 d0
0 0 0 0 a3 a2 a1 a0
0 0 0 d4 d3 d2 d1 d0
0 0 0 1 0 0 0 0
0 0 0 d4 d3 d2 d1 d0
0 0 0 1 0 0 0 1
0 0 0 1 0 0 1 0
0 0 0 d4 d3 d2 d1 d0
0 0 0 1 0 0 1 1
0 0 0 1 0 1 0 0
0 0 0 d4 d3 d2 d1 d0
0 0 0 1 0 1 0 1
d7 d6 d5 d4 d3 d2 d1 d0
0 0 0 1 0 1 1 1
0 0 0 0 0 0 0 1/0
0 0 0 1 1 0 0 0
0 0 0 0 0 0 0 1/0
0 0 0 1 1 0 0 1
0 0 0 0 0 0 0 1/0
0 0 0 1 1 0 1 0
0 0 0 0 0 0 0 1/0
0 0 0 1 1 0 1 1
0 0 0 0 0 0 0 1/0
0 0 0 1 1 1 0 0
0 0 0 0 0 0 d1 d0
0 0 0 1 1 1 0 1
d7 d6 d5 d4 d3 d2 d1 d0
0 0 0 1 1 1 1 1
d7 d6 d5 d4 d3 d2 d1 d0
0 0 1 0 0 0 0 0
0 0 1 0 0 0 0 1
0 0 0 0 0 0 0 d16
0 0 1 0 0 0 1 0
0 0 0 0 d3 d2 d1 d0
Note
16 GrayScales 160X160 STN LCD Controller
Rev 1.11 Feb. 2002
3)
12
Preliminary Product Information
Fax: 886-3-563-0879
Homepage:http://www.aimtron.com.tw
Function
Write display data into SRAM (One byte command).
The write pulse of the MPU must be the multiples of 4
or 8 is dependant on the DFORMAT. (See
Read display data from SRAM (One byte command).
The read pulse of the MPU must be the multiples is
independant on the DFORMAT. (See
Set gamma table. Address(a3—a0) is from 0 to 15.
Data(d4—d0) is from 0 to 31. (See
Window start column address = XWS * 8.
Window start row address. Range is from 0 to 159.
Window end column address = XWE*8.
Window end row address. Range is from 0 to 159.
Panel column size= XP *8.
The minmum value of the XP is 3.
Panel row size.
Segment direction. (See
0: L R 1: R L
Display mode.
0:normal 1:reverse
Display mode.
0:normal 1: off
Set 0 then reset.
After reset, all registers return to their default value.
Row direction.
0: U D 1: D U
Test mode. Set to 0 for normal operation.
First line address.
Frame rate=Fosc / (CLINE * (YP+1) )
Cline must be greater than 4*XP+12.
(Note
Background color.
4)
(Note
AT3210
Note
1)
5)
Note
Note
Note
5)
2)
5)

Related parts for at3210