is45s16100c1 Integrated Silicon Solution, Inc., is45s16100c1 Datasheet - Page 36

no-image

is45s16100c1

Manufacturer Part Number
is45s16100c1
Description
512k Words X 16 Bits X 2 Banks 16-mbit Synchronous Dynamic Ram
Manufacturer
Integrated Silicon Solution, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
is45s16100c1-7BLA1
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
is45s16100c1-7BLA1-TR
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
is45s16100c1-7TLA
Manufacturer:
ISSI
Quantity:
663
Part Number:
is45s16100c1-7TLA1
Manufacturer:
ISSI
Quantity:
8 000
Part Number:
is45s16100c17BLA1
Manufacturer:
OSRAM
Quantity:
2 929
36
IS45S16100C1
Bank Active Command Interval
When the selected bank is precharged, the period trp
has elapsed and the bank has entered the idle state, the
bank can be activated by executing the active
command. If the other bank is in the idle state at that
time, the active command can be executed for that bank
after the period t
banks will be in the active state. When a bank active
command has been executed, a precharge command
must be executed for
Clock Suspend
When the CKE pin is dropped from HIGH to LOW during a
read or write cycle, the IS45S16100C1 enters clock suspend
mode on the next CLK rising edge. This command reduces
the device power dissipation by stopping the device internal
clock. Clock suspend mode continues as long as the CKE
pin remains low. In this state, all inputs other than CKE pin
are invalid and no other commands can be executed. Also,
the device internal states are maintained. When the CKE
pin goes from LOW to HIGH clock suspend mode is
terminated on the next CLK rising edge and device operation
resumes.
CAS latency = 3
CAS latency = 2, burstlength = 4
COMMAND
COMMAND
COMMAND
RRD
CLK
CLK
has elapsed. At that point both
CKE
CLK
BANK ACTIVE (BANK 0)
BANK ACTIVE (BANK 0)
DQ
ACT 0
ACT 0
READ (BANK 0)
READ 0
t
t
RRD
RCD
Integrated Silicon Solution, Inc. — www.issi.com —
D
OUT
CLOCK SUSPEND
BANK ACTIVE (BANK 1)
BANK ACTIVE (BANK 0)
0
READ 0
ACT 1
that bank within the ACT to PRE command period (t
max). Also note that a precharge command cannot be
executed for an active bank before t
After a bank active command has been executed and the
trcd period has elapsed, read write (including auto-precharge)
commands can be executed for that bank.
The next command cannot be executed until the recovery
period (t
Since this command differs from the self-refresh command
described previously in that the refresh operation is not
performed automatically internally, the refresh operation
must be performed within the refresh period (tref). Thus the
maximum time that clock suspend mode can be held is just
under the refresh cycle time.
D
CKA
OUT
) has elapsed.
1
D
OUT
2
D
OUT
RAS
(min) has elapsed.
3
ISSI
1-800-379-4774
01/03/06
Rev. C
RAS
®

Related parts for is45s16100c1