at49sv322a ATMEL Corporation, at49sv322a Datasheet - Page 13

no-image

at49sv322a

Manufacturer Part Number
at49sv322a
Description
32-megabit 2m X 16/4m X 8 1.8-volt Only Flash Memory
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT49SV322A
Manufacturer:
ATMEL
Quantity:
6
Part Number:
at49sv322a-80CI
Manufacturer:
ATMEL
Quantity:
1
Part Number:
at49sv322a-80CI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49sv322a-80CU
Manufacturer:
ATMEL
Quantity:
526
Part Number:
at49sv322a-80CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49sv322a-80TI
Manufacturer:
ATM
Quantity:
2 600
Part Number:
at49sv322a-80TI
Manufacturer:
ATM
Quantity:
2 600
Part Number:
at49sv322a-80TU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
6. Command Definition Table
Notes:
3360E–FLASH–10/05
Command
Sequence
Read
Chip Erase
Sector Erase
Byte/Word Program
Dual Byte/Word
Program
Enter Single Pulse
Program Mode
Single Pulse
Byte/Word Program
Sector Lockdown
Erase/Program
Suspend
Erase/Program
Resume
Product ID Entry
Product ID Exit
Product ID Exit
Program Protection
Register
Lock Protection
Register - Block B
Status of Block B
Protection
Set Configuration
Register
CFI Query
1. The DATA FORMAT shown for each bus cycle is as follows; I/O7 - I/O0 (Hex). In word operation I/O15 - I/O8
2. Since A11 is a Don’t Care, AAA can be replaced with 2AA.
3. SA = sector address. Any byte/word address within a sector can be used to designate the sector address (see pages
4. Once a sector is in the lockdown mode, data in the protected sector cannot be changed unless the chip is reset or power
5. Either one of the Product ID Exit commands can be used.
6. If data bit D1 is “0”, block B is locked. If data bit D1 is “1”, block B can be reprogrammed.
7. The default state (after power-up) of the configuration register is “00”.
8. Bytes of data other than F0 may be used to exit the Product ID mode. However, it is recommended that F0 be used.
9. This fast programming option enables the user to program two words in parallel only when V
(9)
are don’t care. The ADDRESS FORMAT shown for each bus cycle is as follows: A11 - A0 (Hex). Address A20 through A11
are don’t care in the word mode. Address A20 through A11 and A-1 are don’t care in the byte mode.
for details).
cycled.
and Addr2, of the two words, D
turing purposes only.
(5)
(5)
Cycles
Bus
1
1
6
6
4
5
6
1
6
1
1
3
3
1
4
4
4
4
Addr
Addr
Addr
XXX
XXX
XXX
X55
555
555
555
555
555
555
555
555
555
555
555
555
1st Bus
Cycle
Data
D
F0
D
98
AA
AA
AA
AA
AA
AA
B0
AA
AA
AA
AA
AA
AA
30
OUT
IN
(8)
IN1
and D
AAA
AAA
Addr
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
AAA
2nd Bus
IN2
Cycle
(2)
(2)
, must only differ in address A0. This command should be used during manufac-
Data
55
55
55
55
55
55
55
55
55
55
55
55
Addr
555
555
555
555
555
555
555
555
555
555
555
555
3rd Bus
Cycle
Data
F0
A0
E0
C0
C0
D0
80
80
80
80
90
90
(8)
Addr
Addr1
Addr
Addr
XXX
555
555
555
555
080
80
4th Bus
Cycle
00/01
D
Data
D
OUT
D
D
AA
AA
AA
AA
X0
IN1
IN
IN
(6)
(7)
AT49SV322A(T)
Addr
Addr2
PP
AAA
AAA
AAA
AAA
5th Bus
= 12V. The Addresses, Addr1
Cycle
Data
D
55
55
55
55
IN2
SA
SA
Addr
555
555
(3)(4)
(3)(4)
6th Bus
Cycle
15 - 18
Data
A0
10
30
60
13

Related parts for at49sv322a