adt7476a Analog Devices, Inc., adt7476a Datasheet - Page 49
adt7476a
Manufacturer Part Number
adt7476a
Description
Dbcool Remote Thermal Controller And Voltage Monitor
Manufacturer
Analog Devices, Inc.
Datasheet
1.ADT7476A.pdf
(72 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adt7476aRQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adt7476aRQZ-REEL
Manufacturer:
ON/安森美
Quantity:
20 000
Enhance Acoustics Register 1 (0x62)
Bit 7 (MIN3) = 0, PWM3 is off (0% PWM duty cycle) when
temperature is below T
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle
below T
Bit 6 (MIN2) = 0, PWM2 is off (0% PWM duty cycle) when
temperature is below T
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle
below T
Bit 5 (MIN1) = 0, PWM1 is off (0% PWM duty cycle) when
temperature is below T
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle
below T
Configuration Register 6 (0x10)
[0] SLOW = 1, slows the ramp rate for PWM changes associated
with the Remote 1 temperature channel by a factor of 4.
[1] SLOW = 1, slows the ramp rate for PWM changes associated
with the local temperature channel by a factor of 4.
[2] SLOW = 1, slows the ramp rate for PWM changes associated
with the Remote 2 temperature channel by a factor of 4.
[7] ExtraSlow = 1, slows the ramp rate for all fans by a factor
of 39.2%.
The following sections list the ramp-up times when the
SLOW bit is set for each temperature monitoring channel.
Enhance Acoustics Register 1 (0x62)
[2:0] ACOU selects the ramp rate for PWM outputs associated
with the Remote Temperature 1 input.
Enhance Acoustics Register 2 (0x63)
[2:0] ACOU3 selects the ramp rate for PWM outputs associated
with the local temperature channel.
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
MIN
MIN
MIN
− T
− T
− T
HYST
HYST
HYST
.
.
.
MIN
MIN
MIN
− T
− T
− T
HYST
HYST
HYST
.
.
.
Rev. 0 | Page 49 of 72
[6:4] ACOU2 selects the ramp rate for PWM outputs associated
with the Remote Temperature 2 input.
When Bit 7 of Configuration Register 6 (0x10) = 1, the above
ramp rates change to the values below.
Setting the appropriate slow bit [2:0] of Configuration
Register 6 (0x10) slows the ramp rate further by a factor of 4.
FAN PRESENCE DETECT
This feature is used to determine if a 4-wire fan is directly
connected to a PWM output. This feature does not work for
3-wire fans. To detect whether a 4-wire fan is connected directly
to a PWM output, the following must be performed in this order:
1.
2.
3.
4.
5.
As the detection time only takes 5 ms, programming the
PWM outputs to 100% and then back to its normal speed is
not noticeable in most cases.
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
000 = 37.5 sec
001 = 18.8 sec
010 = 12.5 sec
011 = 7.5 sec
100 = 4.7 sec
101 = 3.1 sec
110 = 1.6 sec
111 = 0.8 sec
000 = 52.2 sec
001 = 26.1 sec
010 = 17.4 sec
011 = 10.4 sec
100 = 6.5 sec
101 = 4.4 sec
110 = 2.2 sec
111 = 1.1 sec
Drive the appropriate PWM outputs to 100% duty cycle.
Set Bit 0 of Configuration Register 2 (0x73).
Wait 5 ms.
Program fans to run at a different speed if necessary.
Read the state of Bits [3:1] of Configuration Register 2
(0x73). The state of these bits reflects whether a 4-wire fan
is directly connected to the PWM output.
ADT7476A