May 2009
Default value for all three bytes
Serial address
Byte addresses
When the APC is on, the eight-bit signed integer compensation value corresponding to the current temperature is taken from
the BIASLUT look-up table, added to the selected APCSET (0, 1, or 2) register and loaded into the V
If DAC Calibration mode is selected in OEMCAL0, a write to any one of the three APCSETn registers will cause the V
to be updated immediately. DAC Calibration mode disables the output of the BIASLUT lookup table, so the unmodified
APCSETn register value propagates directly to the DAC.
The eight-bit value presented to the V
A valid OEM password is required for access to these registers. These registers are non-volatile and will be maintained through
power and reset cycles.
Default value for all three bytes
Serial address
Byte address
When the APC is on, the eight-bit signed integer compensation value corresponding to the current temperature is taken from
the MODLUT look-up table, added to the selected MODSET (0, 1, or 2) register and loaded into the V
If DAC Calibration mode is selected in OEMCAL0, a write to any one of the three MODSETn registers will cause the V
to be updated immediately. DAC Calibration mode disables the output of the MODLUT lookup table, so the unmodified
MODSETn register value propagates directly to the DAC.
The eight-bit value presented to the V
A valid OEM password is required for access to these registers. These registers are non-volatile and will be maintained through
power and reset cycles.
read/write
read/write
D[7]
D[7]
read/write
read/write
D[6]
D[6]
Modulation Setpoint 0, 1, and 2 (MODSET0, MODSET1, and MODSET2)
APC Setpoint 0, 1, and 2 (APCSET0, APCSET1, APCSET2)
read/write
read/write
D[5]
D[5]
BIAS
MOD
DAC is always available for readback in the APCDAC register.
DAC is always available for readback in the MODDAC register.
Automatic Power Control Setpoint
0000 0000 b = 00 h
A6 h
APCSET0: 3 = 03 h
APCSET1: 4 = 04 h
APCSET2: 5 = 05 h
0000 0000 b = 00 h
A6 h
MODSET0: 6 = 06 h
MODSET1: 30 = 1E h
MODSET2: 31 = 1F h
read/write
read/write
Nominal V
D[4]
D[4]
MOD
Setpoint
read/write
read/write
59
D[3]
D[3]
read/write
read/write
D[2]
D[2]
hbwhelp@micrel.com
read/write
read/write
BIAS
MOD
D[1]
D[1]
DAC.
DAC.
or (408) 955-1690
read/write
read/write
M9999-052709-A
BIAS
MOD
D[0]
D[0]
DAC
DAC
MIC3003