Datasheet - D e t a i l e d D e s c r i p t i o n
Figure 4. State Transition Diagram
RESET
Wait for otp_load
OTP_INT
Completes in 32 cycles
of lp_clk
STOP
1.5msec &
Analog Stablization
NORM
A_STB
NORM
period
Wait for 1.5msec
NORM
or
stop
Wait for x
SBM_ON
Wait for TT1
SBM
SBM_OFF
number of
timeout
conversions
7.4.1 Normal Mode 1 (NOM1)
On Power-on-reset of the device, AS8510 goes into STOP State.
Transition to Normal mode1 (NOM1) occurs when the “START BIT” D0 of Mode Control Register MOD_CTL_REG in
Table 33
is set to “1”
through the serial port SPI. Data Rate of voltage and current channels can be independently programmed and both the channels generate
interrupts for every output available from ADC. The interrupt signal is generated on the INT pin. The width of the interrupt pulse is eight cycles of
lp_clk. The data is stable up to the next interrupt. If the data rate is different for the two channels, the interrupt rate would follow the higher rate
among the two channels. Data update can be known by reading the status register. The functionality is explained in the waveform shown in
Figure
5. When the device is configured to NOM1 Mode from any mode the configuration should be through the STOP state only.
www.austriamicrosystems.com/AS8510
Revision 3.4