max5523euat Maxim Integrated Products, Inc., max5523euat Datasheet - Page 15

no-image

max5523euat

Manufacturer Part Number
max5523euat
Description
Dual, Ultra-low-power, 10-bit, Voltage-output Dacs
Manufacturer
Maxim Integrated Products, Inc.
Datasheet
Table 2. Serial-Interface Programming Commands
X = Don’t care.
*Standby mode can be entered from normal operation only. It is not possible to enter standby mode from shutdown.
C3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
CONTROL BITS
C2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
C1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
______________________________________________________________________________________
C0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
INPUT DATA
XXXXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
10-bit data
10-bit data
10-bit data
10-bit data
10-bit data
10-bit data
D9, D8,
D9, D8,
D9, D8,
D9–D0
S1 AND S0
SUB-BITS
10-Bit, Voltage-Output DACs
00
00
00
00
00
00
00
00
00
00
No operation; command is ignored.
Load input register A from shift register; DAC registers unchanged;
DAC outputs unchanged.
Load input register B from shift register; DAC registers unchanged;
DAC outputs unchanged.
Command reserved. Do not use.
Command reserved. Do not use.
Command reserved. Do not use.
Command reserved. Do not use.
Command reserved. Do not use.
Load DAC registers A and B from respective input registers; DAC
outputs A and B updated; MAX5523/MAX5525 enter normal
operation if in standby or shutdown; MAX5522/MAX5524 enter
normal operation if in shutdown.
Load input register A and DAC register A from shift register; DAC
output A updated; Load DAC register B from input register B; DAC
output B updated; MAX5523/MAX5525 enter normal operation if in
standby or shutdown; MAX5522/MAX5524 enter normal operation
if in shutdown.
Load input register B and DAC register B from shift register; DAC
output B updated; Load DAC register A from input register A; DAC
output A updated; MAX5523/MAX5525 enter normal operation if in
standby or shutdown; MAX5522/MAX5524 enter normal operation
if in shutdown.
Command reserved. Do not use.
MAX5523/MAX5525 enter standby*, MAX5522/MAX5524 enter
shutdown. For the MAX5523/MAX5525, D9 and D8 configure the
internal reference voltage (Table 3).
MAX5522–MAX5525 enter normal operation; DAC outputs reflect
existing contents of DAC registers. For the MAX5523/MAX5525,
D9 and D8 configure the internal reference voltage (Table 3).
MAX5522–MAX5525 enter shutdown; DAC outputs set to high
impedance. For the MAX5523/MAX5525, D9 and D8 configure the
internal reference voltage (Table 3).
Load input registers A and B and DAC registers A and B from shift
register; DAC outputs A and B updated; MAX5523/MAX5525 enter
normal operation if in standby or shutdown; MAX5522/MAX5524
enter normal operation if in shutdown.