ltc2978 Linear Technology Corporation, ltc2978 Datasheet - Page 34

no-image

ltc2978

Manufacturer Part Number
ltc2978
Description
Octal Pmbus Power Supply Monitor And Controller With Eeprom
Manufacturer
Linear Technology Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC2978
Manufacturer:
TEMIC
Quantity:
73
Part Number:
ltc2978A
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
ltc2978ACUP
Manufacturer:
LTNEAR
Quantity:
20 000
Part Number:
ltc2978ACUP#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
ltc2978ACUP#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Company:
Part Number:
ltc2978ACUP#TRPBF
Quantity:
493
Part Number:
ltc2978AIUP
Manufacturer:
LTNRAR
Quantity:
20 000
Part Number:
ltc2978CUKH#PBF
Manufacturer:
LT
Quantity:
680
Part Number:
ltc2978CUP
Manufacturer:
LT
Quantity:
357
Part Number:
ltc2978CUP
Quantity:
6 218
Part Number:
ltc2978CUP#PBF
Manufacturer:
LINEAR
Quantity:
16 050
Company:
Part Number:
ltc2978CUP#TRPBF
Quantity:
48
ADC Monitoring Commands
READ_VIN
This command returns the most recent ADC measured
value of the voltage measured at the V
READ_VIN Data Contents
READ_VOUT
This command returns the most recent ADC measured
value of the channel’s output voltage. When odd channels
are configured to measure current, the data contents have
a slightly modified meaning, as described in the second
table below.
READ_VOUT Data Contents
READ_VOUT Data Contents—for Odd Channels Configured to
Measure Current
LTC2978
operaTion

b[15:0] Read_vin[15:0] The data uses the linear format:
b[15:0] Read_vout[15:0] The data uses the linear mode format as
b[15:0] Read_vout[15:0] The data uses the linear format:
BIT(S) SYMBOL
BIT(S) SYMBOL
Bit(s) Symbol
OPERATION
V(Symbol) = Y • 2
where N = b[15:11] is a 5-bit two’s
complement integer and
Y = b[10:0] is an 11-bit two’s complement
integer
Units: V
Operation
V(Symbol) = Y • 2
where N = b[15:11] is a 5-bit two’s
complement integer and
Y = b[10:0] is an 11-bit two’s complement
integer
Units: mV
OPERATION
defined by VOUT_MODE:
V(Read_vout) = Y • 2
an unsigned integer and N = Vout_mode_
parameter is a 5-bit two’s complement
exponent that’s hardwired to –13 decimal.
Units: V.
N
N
N
IN_SNS
where Y = b[15:0] is
pin.
READ_TEMPERATURE_1
This command returns the most recent ADC measured
value of junction temperature in °C as determined by the
LTC2978’s internal temperature sensor.
READ_TEMPERATURE_1 Data Contents
PMBUS_REVISION
The PMBUS_REVISION command register is read only and
reports the LTC2978 compliance to the PMBus standard
revision 1.1.
PMBUS_REVISION Data Contents
b[15:0] Read_temperature_1 [15:0] The data uses the linear format:
BIT(S) SYMBOL
BIT(S) SYMBOL
b[7:0] PMBus_rev
OPERATION
Reports the PMBus standard revision
compliance. This is hard-coded to ‘h11 for
revision 1.1.
OPERATION
Temp(Symbol) = Y • 2
Where N = b[15:11] is a 5-bit
two’s complement integer and
Y = b[10:0] is an 11-bit two’s
complement integer
Units: °C.
N
2978fa