rr2ba-ul-ac6 IDEC Corporation, rr2ba-ul-ac6 Datasheet - Page 31

no-image

rr2ba-ul-ac6

Manufacturer Part Number
rr2ba-ul-ac6
Description
Ru/rr/rh/rm/ry & Latch Relays Relays Sockets
Manufacturer
IDEC Corporation
Datasheet
(04/10/25)
Specifications
Note: Above values are initial values.
∗1: Measured using 5V DC, 1A voltage drop method
∗2: Measured at the rated voltage (at 20°C), excluding contact bouncing
∗3: Relays with indicator or diode: 1000V AC, 1 minute
Characteristics (Reference Data)
• • • • Maximum Switching Capacity
• • • • Continuous Load Current vs. Operating Temperature Curve
Contact Type
Contact Material
Contact Resistance
Minimum Applicable Load
Operate Time
Release Time
Power Consumption
(approx.)
Insulation Resistance
Dielectric Strength
Operating Frequency
Vibration Resistance
Shock Resistance
Electrical Life
Mechanical Life
Operating Temperature
Operating Humidity
Weight (approx.)
(Basic Type, With Check Button, and Top Bracket Mounting Type)
(RY2)
(RY2)
Release time of relays with diode: 40 ms maximum
0.5
0.1
5
3
1
1
100
90
80
70
60
50
40
30
20
10
0
5
1
Load Current (A)
Note: The rated voltage is
Load Voltage (V)
AC Coil
10
DC inductive
∗ 1
∗ 2
∗ 2
∗ 4
applied to the coil.
2
DC Coil
3
Gold-plated silver
50 m Ω maximum
24V DC, 5 mA; 5V DC, 10 mA (reference value)
20 ms maximum
20 ms maximum
AC: 1.1 VA (50 Hz), 1 VA (60 Hz)
DC: 0.8W
100 M Ω minimum (500V DC megger)
Between live and dead parts:
Between contact and coil:
Between contacts of different poles:
Between contacts of the same pole:
Electrical:
Mechanical:
Damage limits:
Operating extremes:
Damage limits:
Operating extremes:
200,000 operations (220V AC, 3A)
50,000,000 operations
–25 to +55°C (no freezing)
45 to 85% RH (no condensation)
23g
50
AC
inductive
AC resistive
1500V AC, 1 minute
1500V AC, 1 minute
1500V AC, 1 minute
1000V AC, 1 minute
100
DC resistive
200 300
DPDT
(RY4)
(RY4)
1800 operations/h maximum
18,000 operations/h maximum
10 to 55 Hz, amplitude 0.5 mm
10 to 55 Hz, amplitude 0.5 mm
1000 m/s
100 m/s
0.5
0.3
0.2
5
3
2
1
1
∗ 3
100
90
80
70
60
50
40
30
20
10
2
Standard Contact
0
2
(DPDT), 200 m/s
AC Coil
1
Load Current (A)
Note: The rated voltage is
Load Voltage (V)
AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz)
DC: 0.9W
Between live and dead parts:
Between contact and coil:
Between contacts of different poles:
Between contacts of the same pole:
100,000 operations (220V AC, 5A)
200,000 operations (220V AC, 3A)
–25 to +55°C (no freezing)
34g
10
DC resistive
DC inductive
applied to the coil.
2000V AC, 1 minute
2000V AC, 1 minute
2000V AC, 1 minute
1000V AC, 1 minute
2
20
∗4: For use under different temperature conditions, refer to Continuous Load
∗5: When the total current of 4 contacts is less than 15A, the operating tem-
DC Coil
RY
30
2
Current vs. Operating Temperature Curve.
The operating temperature range of relays with indicator or diode is –25
to +40°C.
perature range is –25 to +70°C.
(4PDT)
3
50
100
4PDT
AC resistive
Series
AC inductive
200 300
Miniature Relays
(RY22)
∗ 5
0.05
0.01
0.5
0.1
1
1
Silver-paradium alloy
100 m Ω minimum
1V DC, 100 µA (reference value)
AC: 1.1 VA (50 Hz), 1 VA (60 Hz)
DC: 0.8W
Between live and dead parts:
Between contact and coil:
Between contacts of different poles:
Between contacts of the same pole:
200,000 operations (110V AC, 1A)
–25 to +55°C (no freezing)
23g
1500V AC, 1 minute
1500V AC, 1 minute
1500V AC, 1 minute
1000V AC, 1 minute
5
Bifurcated Contact
10
Load Voltage (V)
DC resistive
DC inductive
DPDT
50
AC
resistive
AC
inductive
100
∗ 3
200 300
31

Related parts for rr2ba-ul-ac6