rr2ba-ul-ac6 IDEC Corporation, rr2ba-ul-ac6 Datasheet - Page 16

no-image

rr2ba-ul-ac6

Manufacturer Part Number
rr2ba-ul-ac6
Description
Ru/rr/rh/rm/ry & Latch Relays Relays Sockets
Manufacturer
IDEC Corporation
Datasheet
RR
Contact Ratings
Note: Inductive load for the rated load — cos ø = 0.3, L/R = 7 ms
• • • • UL Ratings
Specifications
Note: Above values are initial values.
∗ 1: Measured using 5V DC, 1A voltage drop method
∗ 2: Measured at the rated voltage (at 20°C), excluding contact bouncing
∗ 3: For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve.
16
Continuous
Contact Material
Contact Resistance
Minimum Applicable Load
Operate Time
Release Time
Power Consumption
(approx.)
Insulation Resistance
Dielectric Strength
Operating Frequency
Vibration Resistance
Shock Resistance
Electrical Life
Mechanical Life
Operating Temperature
Operating Humidity
Weight (approx.) (Basic type)
Current
10A
240V AC
120V AC
30V DC
Voltage
Series
Allowable Contact Power
1650VA AC
300W DC
Resistive
Load
Power Relays
Maximum Contact Capacity
1100VA AC
150W DC
Inductive
Resistive
Load
10A
10A
10A
Pin Terminal
Blade Terminal
∗ 1
∗ 2
∗ 2
∗ 3
110V AC
220V AC
30V DC
Voltage
General use
7.5A
7A
7A
Rated Load
Resistive
Silver
30 m Ω maximum
24V DC, 10 mA; 5V DC, 20 mA (reference value)
25 ms maximum
25 ms maximum
AC: 3 VA (50 Hz), 2.5 VA (60 Hz)
DC: 1.5W
100 M Ω minimum (500V DC megger)
Between live and dead parts:
Between contact and coil:
Between contacts of different poles:
Between contacts of the same pole:
Between live and dead parts:
Between contact and coil:
Between contacts of different poles:
Between contacts of the same pole:
Electrical:
Mechanical:
Damage limits:
Operating extremes:
Damage limits:
Operating extremes:
200,000 operations (220V AC, 5A)
10,000,000 operations
–25 to +40°C (no freezing)
5 to 85% RH (no condensation)
RR2P: 90g, RR3P/RR3PA: 96g, RR1BA/RR2BA/RR3B: 82g
Load
7.5A
10A
10A
Horse Power
Raging
1/3 HP
1/4 HP
Inductive
Load
7.5A
5A
5A
1800 operations/h maximum
18,000 operations/h maximum
10 to 55 Hz, amplitude 0.5 mm
10 to 55 Hz, amplitude 0.5 mm
1000 m/s
100 m/s
• • • • CSA Ratings
• • • •
AC: cos ø = 1.0, DC: L/R = 0 ms
TÜV Ratings
2
2
240V AC
120V AC
100V DC
240V AC
30V DC
30V DC
Voltage
1500V AC, 1 minute
1500V AC, 1 minute
1500V AC, 1 minute
1000V AC, 1 minute
2000V AC, 1 minute
2000V AC, 1 minute
2000V AC, 1 minute
1000V AC, 1 minute
Resistive
10A
10A
10A
10A
10A
General use
7.5A
0.5A
7.5A
7A
(04/10/25)