SC2-2 displays
Displays for the switching state of the OSSD and status displays for indicating the operating status are lo-
cated on the front plate of the two modules of the SC2-2.
Table 2.5: Status displays
If an error is present, the yellow LED flashes, indicating readiness for startup. The red LEDs E1 and E2 dis-
play the error that has been determined.
Display
OFF
ON
Start
R1
R2
LED
Yellow
Yellow
Yellow
Green
Red
Meaning
Continuous light:Protective field free, OSSD off, readiness for
startup,
Flashing
Status of light barrier 1
Off: Interrupted
On: Light beam free
Flashing: Light beam free, level below function reserve:
Status of light barrier 2
Off: Interrupted
On: Light beam free
Flashing: Light beam free, level below function reserve
OSSD output turned on
OSSD output turned off
activate restart button
System error (see Status E1, E2)