smp100lc STMicroelectronics, smp100lc Datasheet
smp100lc
Available stocks
Related parts for smp100lc
smp100lc Summary of contents
Page 1
... ITU-T K20/K21 (lightning and AC power fault tests), TIA/EIA-IS-968 (formely FCC Part 68 lightning tests), UL60950 (AC power fault tests). Moreover, the use of the TCP1.25A allows the SMP100LC-xxx to be safe for the 2nd level (B criteria) AC power fault tests. March 2007 Trisil™ for telecom equipment protection ...
Page 2
... C) amb Parameter Figure 1) (1) SMP100LC Minimum serial Current resistor to meet waveform standard (Ω) 2/10 µs 0 10/1000 µs 0 2/10 µs 0 2/10 µ 5/310 µ 5/310 µ ...
Page 3
... Leakage current Capacitance Type SMP100LC-8 SMP100LC-25 SMP100LC-35 SMP100LC-65 SMP100LC-90 SMP100LC-120 SMP100LC-140 SMP100LC-160 SMP100LC-200 SMP100LC-230 SMP100LC-270 SMP100LC-320 SMP100LC-360 SMP100LC-400 1. I measured See Figure 15: Test circuit 1 for Dynamic I 3. See Figure 16: Test circuit 2 for I 4. See Figure 17: Test circuit 3 for dynamic I 5 ...
Page 4
... Figure =25° 2000 1000 100 100 125 SMP100LC Non repetitive surge peak on-state current versus overload duration F=50Hz T initial = 25°C j t(s) 1E-1 1E+0 1E+1 1E+2 Relative variation of holding current versus junction temperature (° Relative variation of leakage ...
Page 5
... ( 100 Line Ex. xDSL line card or terminal Fuse TCP 1.25A Tip S SMP100LC-xxx Gnd SMP100LC-xxx Fuse TCP 1.25A Ring S Typical circuit for central office side F =1MHz RMS T = 25°C j 300 5/12 ...
Page 6
... Application information Figure 11. Test method of the board with fuse and Trisil These topologies, using SMP100LC from ST and TCP1.25A from Cooper Bussmann, have been functionally validated with a Trisil glued on the PCB. Following example was performed with SMP100LC-270 Trisil. For more information, see Application Note AN2064. ...
Page 7
... SMP100LC Figure 13. Trisil action while fuse remains operational Test conditions: 600 1.1 s (first level), T Test result: Fuse and Trisil OK after test in accordance with GR1089 requirements. Figure 14. High current AC power test: the fuse acts like a switch by opening the circuit Test conditions: ...
Page 8
... ton = 20ms Vout 1/4 ➔ Ω < 200V V = 250 140 BO OUT RMS ≥ ➔ Ω 200V V = 480 240 BO OUT RMS SMP100LC parameters BO 83 Ω 46 µH 0. Ω 470 Ω 46 µ 140Ω 240Ω VBO DUT measurement IBO measurement ...
Page 9
... SMP100LC Figure 17. Test circuit 3 for dynamic I V BAT This is a GO-NOGO test which allows to confirm the holding current (I ) level in a functional test circuit. TEST PROCEDURE 1/ Adjust the current level at the I value by short circuiting the AK of the D.U.T. 2/ Fire the D.U.T. with a surge current 3/ The D ...
Page 10
... Package information 4 Package information Table 5. SMB Dimensions Figure 18. Footprint (dimensions in mm) 10/12 Ref 1.62 2.60 1.62 5.84 SMP100LC Dimensions Millimeters Inches Min. Max. Min. Max. 1.90 2.45 0.075 0.096 0.05 0.20 0.002 0.008 1.95 2.20 0.077 0.087 0.15 0.40 0.006 0.016 5.10 5.60 0.201 0.220 4.05 4.60 0.159 0.181 3.30 3.95 0.130 0.156 ...
Page 11
... L16 L20 L23 L27 L32 L36 L40 Revision 9 Absolute ratings values, table 3 on page 2, updated. 10 SMP100LC-320, SMP100LC-360 and SMP100LC-400 addition. 11 Telecom Circuit Protector added in Description. Reformatted to current standards. SMB 12 updated. Standards compliance paragraphs added to Ordering information Weight Base qty Delivery mode 0.11 g 2500 Tape & ...
Page 12
... Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan - Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America 12/12 Please Read Carefully: © 2007 STMicroelectronics - All rights reserved STMicroelectronics group of companies www.st.com SMP100LC ...